INSTALLATION: 3208-HRFS/3208-HRS
WIRING Models 3208-HRFS (Rain Freeze Sensor) or 3208-HRS (Rain Sensor)
IMPORTANT: The rain sensor is designed for 24-VAC irrigation controllers only. All wiring must
conform to applicable local building codes and regulations. K-Rain Rain Sensors will not work
with open circuit timers.
1. Installing the wired rain sensor on Sensor Terminals, simply:
Find the controller sensor terminals
(generally marked “SENSOR”, “SEN” or “S”)
and attach the Rain Sensor control wires
directly to these terminals in any order.
NOTE:
1. There may be a jumper tab or wire between the sensor terminals that must be removed.
2. If a rain sensor will not be installed, the preinstalled jumper wire must remain installed
on the SENSOR terminals.
3. The manual activation cycle of some controllers bypasses the sensor inputs.
The controller must be in Automatic mode in order for the sensor to work properly.
2. Installing the wired rain sensors 3208-HRFS or 3208-HRS into controllers
without sensor terminals and without pump start/master valve:
FIGURE 1
A. 24-VAC Solenoid Valves Only (No Pump Start Relay See Figure 1). With the two wires from
the rain sensor at the controller, locate the “common ground” wire of the solenoid valves.
If it is connected to the common terminal on the controller disconnect it. Attach one wire
of the rain sensor to the “common” terminal (usually marked “COM”) on the controller.
Attach the other wire of the rain sensor to the common wire leading to the valves.
NOTE: The common wire to the valves does not have to be interrupted at the controller.
The rain sensor may be wired anywhere along the common wire line.
1234
COM
Irrigation System Controller
Wire ConnectorCommon Wire from Valves
To Valves
24 VAC
1234
COM
PUMP/
MV
Irrigation System Controller
Pump Start Relay/
Master Valve
Wire ConnectorCommon Wire from Valves
To Valves
24 VAC
05
www.krain.com
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for K-rain 3208-WRFS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of K-rain 3208-WRFS in the language / languages: English as an attachment in your email.

The manual is 1,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info