23027
27
Zoom out
Zoom in
Previous page
1/56
Next page
EN
27
Iris Lock
Use this function in the following situations:
When shooting a moving subject.
When the distance to the subject changes (so its size
in the LCD monitor or the viewfinder changes), such
as when the subject is backing away.
When shooting on a reflective natural background
such as at the beach or when skiing.
When shooting objects under a spotlight.
When zooming.
When the subject is close, keep the iris locked. Even
when the subject moves away from you, the image will
not darken or brighten.
Before the following steps, perform steps 1 through
4 of Exposure Control ( pg. 26).
5 Adjust zoom so that the subject fills the LCD monitor
or the viewfinder, then press and hold the MENU/
VOLUME wheel % for over 2 seconds. The exposure
control indicator ) and w appear. Press the
MENU/VOLUME wheel % in. w changes to
and the iris is locked.
To Return To Automatic Iris Control . . .
..... rotate the MENU/VOLUME wheel % to display
AUTO then press it in step 4. The exposure
control indicator ) and w disappear. Or, set
the Power Switch y to .
To Lock The Exposure Control And The Iris . . .
..... after step 4 of Exposure Control ( pg. 26),
adjust the exposure rotating the MENU/VOLUME
wheel %. Then lock the iris in step 5 of Iris Lock.
For automatic locking, rotate the MENU/VOLUME
wheel % to select AUTO, then press it in step 4.
The iris becomes automatic after about 2 seconds.
Iris
Like the pupil of the human eye, it contracts in well-lit
environments to keep too much light from entering, and
dilates in dim environments to allow in more light.
FOR RECORDING
Manual White Balance Operation
Perform Manual White Balance when shooting under
various types of lighting.
1 Follow steps 1 through 4 of the white balance
adjustment, and select MWB.
2 Hold a sheet of plain white paper in front of the lens.
Adjust zoom or position yourself so that the white paper
fills the screen.
3 Press the MENU/VOLUME wheel % in until
begins blinking rapidly.
When the setting is completed, resumes normal
blinking.
4 Press the MENU/VOLUME wheel % in twice. The
Menu Screen closes and the Manual White Balance
indicator ( is displayed.
NOTES:
In step 2, it may be difficult to focus on the white paper. In
such a case, adjust focus manually (
pg. 26).
A subject can be shot under various types of lighting
conditions indoors (natural, flourescent, candlelight, etc.).
Because the color temperature is different depending on
the light source, the subject tint will differ depending on
the white balance settings. Use this function for a more
natural result.
Once you adjust white balance manually, the setting is
retained even if the power is turned off or the battery
removed.
White Balance Adjustment
A term that refers to the correctness of color reproduc-
tion under various lighting. If the white balance is
correct, all other colors will be accurately reproduced.
The white balance is usually adjusted automatically.
However, more advanced camcorder operators control
this function manually to achieve a more professional
color/tint reproduction.
1 Set the Power Switch y to while pressing
down the Lock Button t located on the switch. Open
the LCD monitor fully or pull out the viewfinder fully.
2 Press the MENU/VOLUME wheel % in. The Menu
Screen appears.
3 Rotate the MENU/VOLUME wheel % to select
(W.BALANCE), then press it.
4 Rotate the MENU/VOLUME wheel % to select the
desired mode.
AUTO: White balance is adjusted automatically
(factory preset).
MWB: White balance is set manually.
FINE: Outdoors on a sunny day.
CLOUD: Outdoors on a cloudy day.
HALOGEN: A video light or similar type of
lighting is used.
5 Press the MENU/VOLUME wheel % in. Selection is
complete. Press the MENU/VOLUME wheel % in
again. The Menu Screen closes and the selected mode
indicator except AUTO appears.
To Return To Automatic White Balance . . .
..... select AUTO in step 4. Or, set the Power Switch
y to .
NOTE:
White balance cannot be used when Sepia or Monotone
(
pg. 23) is activated.
1 GR-D90/70/30US EN 23-34 02.11.6, 3:12 PM27
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for JVC GR-D70 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of JVC GR-D70 in the language / languages: English as an attachment in your email.

The manual is 2,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of JVC GR-D70

JVC GR-D70 User Manual - Dutch - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info