PELLET BURNING STOVES
INSTALLATION AND MAINTENANCE MANUAL
34
is below plug
C
”. (fig.16).
CLEANING THE LOWER COMPARTMENT
Remove the ash drawer
G
, unscrew the screws and remove the plug
E
and with the nozzle of a vacuum cleaner to
remove the soot and ash which has accumulated in the exchanger
H
”. Also remove the grate
“F”
and clean it every
2/3 days as explained in chap. 5.1
ATTENTION:
It is advisable to carry out the cleaning of the lower compartment once a week and in any case
according to the fuel consumption.
5.2.1.2. CLEANING THE EXCHANGER AND PIPE UNIT
(SUITE/MUSA and CLUB):
CLEANING THE UPPER COMPARTMENT
When the stove is cold, remove the top, remove the ceramics/ sides as described in section.3.3., loosening the relative
fastening screws before removing the drivers
“B”
and then remove the boiler cover
“C”
. At this point, remove the
turbulators
“D”
and using a rigid rod or a bottle brush, clean the internal pipe unit and the turbulators, removing all of
the accumulated ash. Check the cover gasket and replace it if necessary
ATTENTION:
It is advisable to carry out the cleaning of the upper exchanger at the end of the season and
possibly by an authorised HANKS technician in order to replace the gasket that
is below plug
C
”. (fig.16a).
CLEANING THE LOWER COMPARTMENT
Remove the ash drawer
G
”, empty it and using the nozzle of a vacuum cleaner remove any ash and soot that may have
built up under the drawer
G
”. Also remove the grate
“F”
and clean it every 2/3 days as explained in chap. 5.1.
Remove the drawer
E
”, empty it and using the nozzle of a vacuum cleaner remove any ash that may have built up in
the housing of the drawer
E
”.
ATTENTION:
It is advisable to carry out the cleaning of the
l
ower compartment
E
once a week and in any
case according to the fuel consumption. Check the seal of the ceramic fibre gaskets on the plug and replace it if
necessary. Check the seal of the door gasket and replace it if necessary. At the end of the season it is necessary to clean
the compartment under the grate and the heat exchanger inside it. This general cleaning should be carried out at the
end of the season in order to facilitate the general removal of all residues of combustion, without waiting too long,
because with time and humidity these residues can become compacted.
5.2.2.
Shutting the stove down (end of season)
In the period when the stove is out of use it must be disconnected
from the electricity mains. For greater safety, especially if there
are children around, we recommend removing the power cable from
the rear of the stove.
(Figure 17)
Before placing the stove in storage, you should remove all pellets from
the hopper with a vacuum cleaner with a long extension. If the fuel is
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Just Fire NB-B35 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Just Fire NB-B35 in the language / languages: English as an attachment in your email.

The manual is 4,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info