PELLET BURNING STOVES
INSTALLATION AND MAINTENANCE MANUAL
16
Always install the heater upstream of the valve gate valve to isolate the same water system or move it move it
if necessary, to perform routine maintenance and / or extraordinary. Connect the heater hoses for not using
the over-constrain the stove to allow the plant and the light shifts. The pressure relief valve (C) must always be connected to a
drain hose. The pipe must be suitable to withstand the high temperature and pressure.
3.3.2. Filling the water network
To load of the heater , the heater must be equipped with a tap ( optional) with a non-return valve (D) in order
to manually fill the network you can use the load tap already on the boiler on the stove .
During that operation, the outlet of any air in the system is guaranteed by the present automatic vent under
the top. To guarantee that the valve discharges air , it is recommended to loosen the grey tap and leave the
red tap locked ( refer to fig. ).
The filling pressure during cold status should be 1 bar.
If during operation the system pressure drops (due to evaporation of
the gas dissolved in water) to values less
than the minimum indicated above, the User shall, acting on the valve
from the load back to the initial value.
For optimal operation of the stove in a operation ( hot) , the boiler
pressure must be 1.5 bar. Do not exceed 2
bar. At the end of the operation always close the filling tap.
3.3.3. Water characteristics
The characteristics of the water for filling the plant, are very important
to avoid the deposition of minerals and the creation of deposits along
the piping within the boiler and heat exchangers. Therefore it is
advised to check with your plumber / fitter the following
characteristics:
•Hardness of water circulating in the system to remedy any
problems and limestone deposits especially in the hot water heat
exchanger. (> 25 ° French
Installing a water softener (if the water hardness is> 25 ° French)
•Fill the system with treated water (demineralized)
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Just Fire NB-B24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Just Fire NB-B24 in the language / languages: English as an attachment in your email.

The manual is 4,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info