634993
51
Zoom out
Zoom in
Previous page
1/60
Next page
Bedrijfs- en storingsmeldingen
Cerapur – 6 720 807 248 (2013/05)
51
15.3 Storingen, die niet worden getoond
Ketelstoringen Verhelpen
Te veel verbrandingsgeluid; bromgeluiden Gassoort controleren.
Gasaansluitdruk controleren ( pagina 36).
Rookgassysteem controleren, eventueel reinigen of herstellen.
Gas-lucht-verhouding controleren, eventueel corrigeren ( pagina 36).
Gasblok controleren ( pagina 43), eventueel vervangen.
Stromingsgeluiden Pompcapaciteit of pompcurve correct instellen en op maximaal vermogen aanpassen.
Opwarming duurt te lang. Pompcapaciteit of pompcurve correct instellen en op maximaal vermogen aanpassen.
Rookgaswaarden niet in orde; CO-gehalte te hoog. Gassoort controleren.
Gasaansluitdruk controleren ( pagina 36).
Rookgassysteem controleren, eventueel reinigen of herstellen.
Gas-lucht-verhouding controleren, eventueel corrigeren ( pagina 36).
Gasblok controleren ( pagina 43), eventueel vervangen.
Ontsteking te hard, te slecht. Met servicefunctie t1 ontstekingstransformator op uitval controleren, eventueel ver-
vangen ( pagina 35).
Gassoort controleren.
Gasaansluitdruk controleren ( pagina 36).
Controleer de netaansluiting.
Controleer de elektroden met kabel, eventueel vervangen ( pagina 39).
Rookgassysteem controleren, eventueel reinigen of herstellen.
Gas-lucht-verhouding controleren, eventueel corrigeren ( pagina 36).
Bij aardgas: controleer de externe gasdebietbewaking, eventueel vervangen.
Controleer de brander, eventueel vervangen ( pagina 39).
Gasblok controleren ( pagina 43), eventueel vervangen.
ZSB-ketels: warm water heeft vieze geur of donkere kleur. Het warmwatercircuit thermisch desinfecteren ( pagina 28).
Beschermanode vervangen.
Condens in de luchtkast Membraan in de mengklep controleren, eventueel vervangen ( pagina 41).
ZWB-ketels: warmwateruitstroomtemperatuur wordt niet
bereikt.
Controleer de turbine, eventueel vervangen ( pagina 41).
Gas-lucht-verhouding controleren, eventueel corrigeren ( pagina 36).
ZWB-ketels: warmwatervolume wordt niet bereikt. Controleren platenwarmtewisselaar ( pagina 42).
Geen functie, het display blijft donker. Controleer de elektrische bedrading op beschadiging.
Vervang defecte kabels.
Zekering controleren, eventueel vervangen ( pagina 25).
Tabel 44 Storingen zonder displayweergave
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junkers ZWB 30-4C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junkers ZWB 30-4C in the language / languages: Dutch as an attachment in your email.

The manual is 6,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Junkers ZWB 30-4C

Junkers ZWB 30-4C User Manual - German - 36 pages

Junkers ZWB 30-4C User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info