20
7.2 Concentrische muurdoorvoer
80/125 met verlengbuizen
7.2 Evacuation murale concentrique
80/125 avec allonges
C13
De maximale equivalente lengte bedraagt
8 meter
(bocht op de geiser niet meerekenen).
La longueur maximale équivalente est
8 mètres
(ne pas prendre en compte le
coude sur le chauffe-bain).
OPGELET: Voor elke extra bocht en afhankelijk
van de hoek, moet de equivalente lengte ver-
minderd worden.
ATTENTION: Pour chaque coude et dépendant
de l’angle
, la longueur équivalente doit être
diminuée.
bocht 90°
coude 90°
bocht 45°
coude 45°
bocht 30°
coude 30°
80/125
2 m
1,5 m
0,7 m
Fig. 19
S
K
150 – 240 mm
155 mm
240 – 330 mm
160 mm
330 – 420 mm
165 mm
420 – 500 mm
170 mm
OPGELET: De rookgasafvoerbuis moet steeds
licht hellend naar de geiser (3 %: m.a.w. onge-
veer 30 mm
per meter buislengte), gemonteerd
worden!
ATTENTION: Le conduit d'évacuation doit
toujours être monté avec une légère pente vers
le chauffe-bain (3 %: c.à.d. environ 30
mm par
mètre de conduit)!
Instelling van het toerental van de extractor:
zie blz. 21 en blz. 44 – 45, tabel 2.
Réglage du régime de l’extracteur:
voir page 21 et pages 44 – 45, tableau 2.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junkers WTD 27 AME CelsiusPur at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junkers WTD 27 AME CelsiusPur in the language / languages: Dutch, French as an attachment in your email.

The manual is 5,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Junkers WTD 27 AME CelsiusPur

Junkers WTD 27 AME CelsiusPur Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info