518365
54
Zoom out
Zoom in
Previous page
1/60
Next page
6 720 805 200 (2013/06 BL-NL)
54
Display
Korte omschrijving
Wat te doen
EA
Vlam wordt niet herkend (geen ionisatie).
Controleer de aarding.
Is de gaskraan open?
Controleer de gasaansluitdruk.
Controleer de netaansluiting.
Controleer de elektrodes en kabels. Indien nodig,
vervangen.
Controleer de rookgasafvoer. Eventueel reinigen of
verbeteren.
Controleer de verhouding gas/lucht (CO
2
).. Eventueel
verbeteren.
Controleer de luchttoevoer van de opstellingsruimte bij
ketels in opstelling B23.
Reinig de uitloop van de condenswatersifon.
Membraan uit het aanzuiggedeelte van de ventilator
nemen en op vervuiling en scheurtjes controleren.
Reinig de warmtewisselaar.
Controleer de gasblok. Indien nodig, vervangen.
Codeerstekker goed vaststeken. Indien nodig,
vervangen.
F0
Interne fout.
De reset-toets gedurende 3 seconden indrukken en
dan loslaten. Hierna start de ketel opnieuw.
Controleer de elektrische stekkers en ontstekingslei-
dingen. Indien nodig de printplaat vervangen.
Controleer de verhouding gas/lucht (CO
2
).
F7
Vlam wordt herkend, hoewel de ketel
uitgeschakeld is.
Controleer elektrodenset op barsten of vervuiling.
Indien nodig, vervangen.
Controleer de rookgasafvoer. Eventueel reinigen of
verbeteren.
Controleer of de printplaat niet vochtig is.
FA
Vlam wordt herkend na gasuitschakeling.
Controleer de gasblok. Indien nodig, vervangen.
Reinig de condenswatersifon.
Controleer elektrodenset. Indien nodig, vervangen.
Controleer de rookgasafvoer. Eventueel reinigen of
verbeteren.
Fd
De reset-toets is per vergissing ingedrukt.
Druk opnieuw op de reset-toets.
Bedrading van de temperatuurbegrenzer en/of de
gasblok controleren op massakortsluiting.
Ontoelaatbaar snelle stijging van de
vertrektemperatuur.
Open de afsluitkranen.
Sluit de verwarmingspomp elektrisch aan de Heatronic
3 aan.
Pompstekker goed vaststeken.
Verwarmingspomp starten of vervangen.
Schakelstand van de pomp correct instellen en
aanpassen in overeenstemming met het
maximumvermogen van de ketel.
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junkers TOP 22-28-3 CE ZWB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junkers TOP 22-28-3 CE ZWB in the language / languages: Dutch as an attachment in your email.

The manual is 4,79 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Junkers TOP 22-28-3 CE ZWB

Junkers TOP 22-28-3 CE ZWB Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info