636481
71
Zoom out
Zoom in
Previous page
1/116
Next page
DHW heating
6 720 645 817 (2010/09)
71
Specification
T
Sp
Cylinder temperature
T
Z
DHW outlet temperature
Constant DHW output
The constant outputs shown refer to the following
parameters:
Flow temperature 90 °C
Outlet temperature 45 °C
Cold water inlet temperature 10 °C
Maximum heat input (heat source input at least the
same as the cylinder coil output)
Reducing the specified heat input will result in a
reduction in the constant output and the performance
factor (N
L
).
Cylinder type Unit SE 300-1
Heat exchanger
Heat transfer Indirect coil
Number of coils
Available capacity l 288
Heating water content l
Heating surface m
2
0.93
Performance factor N
L
1)
to DIN 4708 at max. output
1) The performance factor N
L
corresponds to the number of residential units to be supplied, each with 3.5 occupants, one standard
bath tub and two further draw-off points.
11.5
Further details
Available amount of DHW (without reheating)
2)
T
Sp
= 60 °C and
- T
Z
= 45 °C
- T
Z
= 40 °C
2) Distribution losses outside the cylinder have not been taken into account.
l
l
441
Standby loss (24 h) to DIN 4753 part 8
2)
kWh/d 1.92
Maximum operating pressure, water bar 10
Maximum operating pressure, heating bar 15
Weight (empty, excl. packaging) kg 50
Colour White
Tab. 39
71


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junkers KBR 120-3 A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junkers KBR 120-3 A in the language / languages: English as an attachment in your email.

The manual is 15,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info