Menu INSTALLATEURSNIVEAU instellen (alleen voor de installateur)
6 720 613 462 (2007/02)
8.1.1 INSTALLATEURSNIVEAU: Systeemconfiguratie
8.1.2 INSTALLATEURSNIVEAU: Verwarmingsparameter
Menustructuur
Systeemconfiguratie
Basisinstelling Instelbereik
Persoonlijke
instelling
Beschrijving
vanaf pagina
Automatisch Systeemconf. starten Nee Nee / Ja
53
Configuratie warm water Combinatie
toestel
Nee / Combinatie toe-
stel / Boiler via toestel /
Boiler via IPM n° 3 ... 10
Circulatiepomp Nee Nee / Aangesloten
Configuratie CV Circuit 1 Ongemengd
zonder IPM
Nee / Ongemengd zon-
der IPM / Ongemengd
met IPM / Gemengd
Afstandsbediening CV Circuit 1 Nee Nee / FB 10 / FB 100
Configuratie CV Circuit 2 Nee Nee / Ongemengd zon-
der IPM / Ongemengd
met IPM / Gemengd
Afstandsbediening CV Circuit 2 Nee Nee / FB 10 / FB 100
ISM 1 Nee Nee / Aangesloten
ISM 2 Nee Nee / Aangesloten
Menustructuur
Verwarmingsparameter
Basisinstelling Instelbereik
Persoonlijke
instelling
Beschrijving
vanaf pagina
CV circuit 1
54
Verwarmingstype in
verwarmingscircuit
Radiatoren Voetpunt / eindpunt /
Vloerverwarming /
Radiatoren / Convecto-
ren
Voetpunt 25°C 10°C ... 85°C °C 56
Eindpunt 75°C 30°C ... 85°C °C 56
Temperatuurkeuze 75°C 30°C ... 85°C °C 56
Maximale aanvoertemperatuur 80°C 30°C ... 85°C °C 56
Ruimte-invloed 30% 0% ... 100% % 56
Ruimte-invloed actief bij Sparen, Eco Sparen, Eco / Verw.-
Sparen- Eco
56
Voeler ruimtetemp.
compensatie
Lagere temp. Voeler in FB10 / Interne
voeler / Lagere temp.
(alleen met FB 10)
56
Ruimtetemperatuur
compensatie
0,0 K –5,0 K ... 5,0 K
K
57
CV uit tot lager temp.niveau Ja Nee / Ja 57
Buitentemperatuur
uitschakeling
20,0°C 10,0°C ... 25,0°C,
99,0°C (= functie uit) °C
57
Vorstgrens temperatuur 3,0°C –5,0°C ... 10,0°C °C 57
IJken ruimte-temp. voeler
FB 10
0,0 K –3,0 K ... 3,0 K
(alleen met FB 10) K
58
Omlooptijd mengklep 140 s 10 s ... 600 s s 58
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junkers FW 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junkers FW 200 in the language / languages: Dutch as an attachment in your email.

The manual is 3,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Junkers FW 200

Junkers FW 200 User Manual - German - 84 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info