Einstellen des Menüs FACHMANN EBENE (nur für den Fachmann)
6 720 800 003 (2011/11)
8.1.2 FACHMANN EBENE: Heizungsparameter
8.1.3 FACHMANN EBENE: Solarsystem konfig.
8.1.4 FACHMANN EBENE: Solarsys. Parameter
Menüstruktur
Heizungsparameter
Grund-
einstellung
Einstellbereich
Persönliche
Einstellung
Beschreibung
ab Seite
Raumtemperaturfühler abglei-
chen
0,0 K 3,0 K ... 3,0 K
K
46
Anpassungsfaktor I 40% 0% ... 100% %
Verstärkungsfaktor V 80% 40% ... 100% %
Aufheizoptimierung Nein Nein | Ja
Maximale Vorlauftemperatur 75 °C 30 °C ... 85 °C °C
Mischerlaufzeit 140 s 10 s ... 600 s s
Menüstruktur
Solarsystem konfig.
Grund-
einstellung
Einstellbereich
Persönliche
Einstellung
Beschreibung
ab Seite
Solar Option E Therm. Desinfek-
tion
Nein Nein | Ja
47
Menüstruktur
Solarsys. Parameter
Grund-
einstellung
Einstellbereich
Persönliche
Einstellung
Beschreibung
ab Seite
1. Standardsystem
48
SP: Einschalttemperaturdif-
ferenz
8 K 3 K ... 20 K
(nicht niedriger als „SP: Ausschalt-
temperaturdifferenz“ +1 K) K
SP: Ausschalttemperaturdif-
ferenz
4 K 2 K ... 19 K
(nicht höher als „SP: Einschalttem-
peraturdifferenz“ – 1 K) K
T2: Max. Temperatur Solar-
speicher
60 °C 15 °C ... 90 °C
°C
Maximale Kollektortempera-
tur
120 °C 100 °C ... 140 °C
°C
SP: Betriebsart Solarpumpe
1. Kollektorfeld
Automatik-
betrieb
Automatikbetrieb | Manuell Ein |
Manuell Aus
PE: Betriebsart Pumpe für
therm. Desinfek.
Automatik-
betrieb
Automatikbetrieb | Manuell Ein |
Manuell Aus
47
Solaroptimierung
49
Fläche 1. Kollektorfeld
0,0 m
2
0,0 m
2
... 150,0 m
2
m
2
Typ 1. Kollektorfeld Flachkollek-
tor
Flachkollektor |
Vakuumröhrenkollektor
Klimazone 90 0 ... 255
Optimierungseinfluss Warm-
wasser
0 K 0 K (= Funktion aus) ... 20 K
K
Solarsystem in Betrieb nehmen Nein Nein | Ja 48
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junkers FR 120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junkers FR 120 in the language / languages: German as an attachment in your email.

The manual is 4,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Junkers FR 120

Junkers FR 120 User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info