Prior to installation
Flat ducts must have an internal cross-
section that equates to that of round
pipes.
There should be no sharp bends.
For operating in exhaust-air mode, a
one-way flap should be mounted inside the
extractor hood unless there is already one
fitted in the outlet duct or wall ventilation
box.
If no one-way flap was enclosed with the
hood, it can be obtained from a specialist
retailer.
Installing the one-way flap:
For optimum extractor hood efficiency:
Short, smooth air exhaust pipe.
As few bends in the pipe as possible.
Diameter of pipe to be as large as
possible and no tight bends in pipe.
If long, rough exhaust-air pipes,
many pipe bends or smaller pipe
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.
The manufacturer of the extractor
hoods accepts no liability for complaints
which can be attributed to the design
and layout of the pipework.
If pipes have different diameters:
Insert sealing strip.
For exhaust-air mode, ensure that
there is an adequate supply of fresh air.
Round pipes
Internal diameter
Flat ducts
Cross-section
l
100 mm
179 cm
2
l
120 mm
113 cm
2
l
150 mm
177 cm
2
Air connector l 150 mm
Mount the pipe
directly onto the air
outlet on the hood.
Attach the reducing
connector (enclosed
or available from
specialist retailer)
to the air pipe and
then attach to the
exhaust-air duct.
Air connector l 120 mm
Mount the pipe
directly onto the air
outlet on the hood.
Attach the reducing
connector (enclosed
or available from
specialist retailer)
to the air pipe and
then attach to the
exhaust-air duct.
Snap the one-way
flap into the air pipe.
The two lightly
sprung flaps must
be able to move
upwards.
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junker JD69WS50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junker JD69WS50 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 2,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info