712105
29
Zoom out
Zoom in
Previous page
1/36
Next page
26
Outer dimensions
(mm)
149.3×38.1×43.4
mm
Weight (g)
Thermometer (with batteries): 86.7 g
Operating
Environment
Temperature: 10°C~ 40°C (50°F–104°F)
Humidity: 15%–95% RH, non-condensing
Atmospheric pressure: 86–106 kPa
The infrared thermometer has been tested and conforms to the standard
ASTM E1965-98. ASTM laboratory accuracy requirements in the display
range of 96.8°F to102.2°F (36°C-39°C) for ear canal IR thermometers is
±0.4°F (±0.2°C). Note that for mercury-in-glass and electronic
thermometers, the requirement per ASTM Standards E667-86 and
E1112-86 is ±0.2°F (±0.1°C).
Security Class
Type of protection against electric shock: internally powered equipment.
Degree of protection against electric shock: Type BF applied part.
Degree of protection against ingress of water:IPX0
Safety degree of using in flammable anesthetic gas blending with air,
oxygen or nitrous oxide: Non-AP/APG
No application parts of the thermometer prevents defibrillation charge
effect.
No application parts of the thermometer output signal.
The thermometer is impermanent installed device.
Storage and Transportation
The thermometer can be transported using general transportation tools.
Severe vibration, shock, or rain must be avoided during transportation.
The thermometer must be packaged and then stored in a well-ventilated
room without corrosive gas. The ambient temperature must be between
–20°C and +55°C-4°F–131°F, the relative humidity must be lower than
95% (non-condensing), and the atmospheric pressure must be 50–106 kPa.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jumper JPD-FR410 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jumper JPD-FR410 in the language / languages: English as an attachment in your email.

The manual is 3,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info