37
SECTION 7
7.1 GENERAL
1. Maximum range: 16 NM
2. Minimum range: Less than 25 m on the 0.125 NM range
3. Range scales: Range Number of Range ring
(NM) Rings Interval(NM)
0.125 2 0.0625
0.25 2 0.125
0.5 2 0.25
0.75 3 0.25
1.0 4 0.25
1.5 6 0.25
3.0 6 0.5
6.0 6 1.0
12.0 6 2.0
16.0 4 4.0
4. Range discriminations: Less than 25 m
5. Range ring accuracy: Better than ± 0.9% ofmaximum range
of the scale in use, or 8 m, whichever is
the greater.
6. Bearing accuracy: ± 1 degree
7. Display device: LCD: 115 × 86.4 mm (320 × 240 dots)
8. Environmental conditions:
Scanner unit Temperature − 15℃ to + 55℃
Humidity Up to 95% at 35℃
Display unit Temperature
− 10℃ to + 50℃ (Except LCD)
0℃ to + 50℃ (LCD)
Humidity Up to 95% at 35℃
SPECIFICATIONS
SPECIFICATIONS