2
Range selection
Changes the radar range.
“+”: Increases the range by one step. (The maximum range is 96 or 120 nautical miles.)
“-”: Decreases the range by one step. (The minimum range is 0.125 nautical mile.)
RINGS indicator selection
Turns on and off the fixed distance scale display. When this is turned on, the intervals of the
range rings will be displayed. When this is turned off, then “OFF” will be displayed.
Pulse width selection
Select the pulse width. There are three pulse widths: Short pulse (SP), middle pulse (MP)
and long pulse (LP). The pulse widths that can be used depend on the range being used. If a
change cannot be made, then nothing will be displayed. This setting is stored for each range.
Tuning indicator mode
Sets the tuning mode to MANUAL or AUTO.
MANUAL AUTO
Manual tuningAutomatic tuning
Bearing mode selection
This has the same function as the [AZI MODE] switch. It switches between North-up (true
bearing), Head-up (relative bearing) and Course-up. Each time this button is clicked it will step
through the settings in the following order: “N UP” “C UP” “H UP”
Motion mode selection
The screen display is changed between the True Motion (TM) and Relative Motion (RM)
displays. Clicking this button will switch between “TM” and “RM.” (R) indicates a relative trail.
(T) indicates a true trail.
Transmission/Standby selection
About three minutes after the [PWR] switch is turned on, the “PREHEAT” indication on the upper
left of the screen will change to “STANDBY.”
STANDBY: Indicates that the unit is in the standby state. Clicking the switch at this time will
change the unit to the transmission state.
TRANSMIT: Indicates that the unit is in the transmission state. Clicking the switch at this time
will change the unit to the standby state.
Change Interswitch connection
This is displayed if Interswitch is connected. The indicator shows the connected scanner and
the connection status of the indicator. When this switch is pressed, a menu to change the
connection states of the scanner and indicator will be displayed. The scanner and indicator
connection states cannot be changed, unless the master indicator is in the standby state.
AIS target refreshed (ACT)
When this switch is pressed, the AIS target will be activated.
AIS target deactivated (DACT)
When this switch is pressed, the activated AIS target is paused.
ARPA symbol indicator selection
Turns the ARPA symbol indicator on or off. The setting is changed each time this button is
clicked.
AIS symbol indicator selection
Turns the AIS symbol indicator on or off. The setting is changed each time this button is
clicked.
67


Need help? Post your question in this forum.

Forumrules
1

Forum

jrc-jma9932sa

Reset search

  • HOW TO CLEAR MTR(FAN) ALARM IN JRC RADAR -9932 SA Submitted on 20-4-2022 at 21:26

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for JRC JMA9932SA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of JRC JMA9932SA in the language / languages: English as an attachment in your email.

The manual is 7,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info