467790
2
Zoom out
Zoom in
Previous page
1/108
Next page
2
1.0 Technical data
Material: Cast iron
Finish: Black paint
Type of fuel: Wood
Max. log length: 30 cm
Smoke outlet: Top, rear
Flue pipe dimension: Ø 150 mm/min. 177 cm
2
cross section
Outside air connection: Alu. flex - Ø 100 mm
Product weight:
Burn chamber: 117 kg
Base, cast iron 39 kg
Pedestal, cast iron 32 kg
Leg, cast iron 33 kg
Jøtul F 471 SHD, F 473 SHD and F 474 SHD
can be delivered with the following sides:
Cast iron sides 27 kg
Aluminium sides 3 kg
Glass sides 5.5 kg
Jøtul F 476 SHD:
Soapstone side panels 150 kg
Optional extra Floor plates, Outside air
connection, Rotating set for
the Jøtul F 473 SHD
Product dimensions, distances: See Fig. 1
Technical data in acc. with EN 13240
Nominal heat output: 6,0 kW
Flue gas mass flow: 6,0 g/s
Recommended chimney draught: 12 Pa
Efficiency: 75%@6 kW
CO emissions (13% O2): 0,08%
Flue gas temperature: 305
o
C
Dust: < 20 mg/m
3
n @ 13% O
2
Burn time: 2.0 kg/h
Operational type: Intermittent
Intermittent combustion here means normal use of a fireplace,
i.e. add more fuel as soon as the fire has burned down to embers.
2.0 Relationship to the
authorities
Installation of a fireplace must be carried out in compliance
with national laws and regulations. All local ordinances,
including those that refer to national and European standards,
must be complied with when products are installed.
The installation can only be put into use after it has been
checked by a qualified inspector.
Contact your local building authorities before installing a
new fireplace.
Table of contents
1.0 Technical data .............................................. 2
2.0 Relationship to the authorities ................... 2
3.0 Safety ............................................................ 3
4.0 Installation ..................................................8
5.0 Daily Use ..................................................... 16
6.0 Maintenance ...............................................17
7.0 Servicing ......................................................18
8.0 Optional Extras ............................................21
9.0 Recycling ......................................................21
10.0 Warranty .....................................................21
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number
when contacting your retailer or Jøtul.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Serial no.
ENGLISH
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jotul F 474 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jotul F 474 in the language / languages: English, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 2,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info