467783
8
Zoom out
Zoom in
Previous page
1/100
Next page
8
Requirements for protection of inflammable
floors in front of the fireplace
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions and
installation requirements.
3.3 Walls
Distance from the wall of flammable material
The fireplace is authorised for use with an uninsulated flue with
the distances to the wall of flammable material as shown in fig 1.
Minimum distance to wall for Jøtul F 365 and Jøtul F 366 with
outside air connection through an outside wall :
Fig. 1 C
3.4 Ceiling
There must be a minimum distance of 1000 mm to a combustible
ceiling above the fireplace.
4.0 Installation
N.B. Check that the fireplace is free of any damage prior to
commencing installation.
The product is heavy! Make sure you have assistance when
erecting and installing the fireplace.
4.1 Prior to installation
1. Standard product supplied in two packages. One with the
fireplace itself and one with optional base in cast-iron/
concrete/glass or pedestal in cast-iron or with three legs.
2. When the product is unpacked, the burn plates, baffle plate,
exhaust deflector, base plate, ash pan and riddling grate are
removed. Also remove the small side burn plates and gasket
for flue pipe which are in the ash pan.
Fig. 3
3. Lift off the top plate with the top grid (fig. 3A) and bowl (fig.3B).
4. Check that the operating handles work (fig. 29 A, B and C).
5. If the rear flue pipe outlet is used, first drill holes (fig. 5 A) in
the cut-out covers for the flue pipe before they are knocked
out with the aid of e.g a ball-pane hammer.
6. Place the wooden block (fig. 5 B) that holds the exhaust
deflectors in position so that the side plates are supported
when the cut-out covers are removed.
7. Spread out the cardboard packaging on the floor. Lay the
stove carefully on its side.
ENGLISH
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jotul F 364 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jotul F 364 in the language / languages: English, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info