Location of
control valve
Functions Water ow direction
Filter Normal ltering to rinse the pool
Water ows through the lter bed
where the sand lter pump lies
and then enters the pool
Backwash
Reverse-direction water ow to
rinse the lter bed
Water ows through the lter bed
where the sand lter pump lies
and is then directly discharged
from the drain outlet.
Rinse
This function is used for rst
startup. Sand in the sand tank
is rinsed and the sand bed after
backwashing is leveled.
Water ows through the lter bed
where the sand lter pump lies
and is then directly discharged
from the drain outlet.
Drain
Discharged directly from the drain
outlet, used to lower water level
or discharge water from the pool
Discharged directly from the
drain outlet of the sand lter
pump without passing through
the lter bed
Recirculation
Circulates pool water without
passing through the lter bed.
Water ows directly into the pool
through the control valve of the
sand lter pump without passing
through the lter bed
Closed
Closed water ow between the
lter and the pool
/
SFP6-16-GB(V1) SFP6-16-GB(V1)
Note: During the operation of the sand lter
pump, check the pressure reading of the
manometer.
Generally, when the pressure of the
recommended sand lter pump is less than
0.2bar (3psi) (green area) , it runs normally.
Note: You must make sure that maintenance
begins only after the sand filter pump is
unplugged. Otherwise serious risks such as
personal injury and even death may occur.
Note: Record the reading of the manometer
during the operation of the sand lt er pump.
When the manometer shows a pressure
of 0.2bar (3psi) or higher, please clean up
the sand bend or replace the sand. Use
"backwash" and "rinse" functions.
Note: regular rinsing according to use
situation is recommended.
Long-term storage and storage in winter
Using the product in a frozen pool may damage the product and invalidate the
quality warranty. If the product has to be used with antifreeze, propylene glycol
may also be used. Propylene glycol is a nontoxic chemical unharmful to any plastic
parts. Other types of antifreeze are highly toxic and may be harmful to the product’s
plastic elements.
1.Before discharging the water or repostioning of the pool, make sure the discharge
direction is towards the discharging ditch and away from the home. Review local
regulations for special water treatment requirements.
2.Switch off the product and remove the power plug.
3.After emptying, remove all connected sand filter pumps, corrugated tubes and
lter hoods on the pool wall.
4.Unscrew the drain valve (8) in an anticlockwise direction to completely empty
water inside the body. The drain plug is at the bottom of the body.
5.Dry the parts of the sand lter pump and corrugated tubes.
6.Lubricate the seal rings and washers in the order below for long-term storage.
7.The best practice for product storage is to dry the parts and motor and replace
them in the original package. To avoid shrinkage or corrosion, do not cover or wrap
the motor with a plastic bag.
8.Please store the motor and parts in a dry place at 32°F (0°C) ~104°F (40°C).
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jilong 290729XX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jilong 290729XX in the language / languages: English as an attachment in your email.

The manual is 3,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jilong 290729XX

Jilong 290729XX User Manual - German - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info