UC-260 Wireless Acoustic Indicator 2 / 2 MFI51300
Doorbell mode
After pressing a doorbell button, the UC-260 will play a selected
melody. Different melodies can be chosen for each button, if desired.
If you want to change a melody, enter the programming mode (See
Adding components) and press the button until a desired melody is
selected.
Detector chime mode
If an enrolled detector is triggered, the UC-260 will play a chosen
melody. The melody can be changed if desired (See Adding
components).
A detector enrolled to the UC-260 can be enrolled to a JA-60 or
JA-65 security control panel too. For example, this way a wireless door
detector can activate a chime with the UC-260 and at the same time it
can trigger an alarm system.
Note: JA-60P motion detector uses a special sleeping mode
feature (can be set to 5 min. or 1 min.). Therefore it cannot detect
more frequent movements in a covered area.
Wireless siren mode
If a control panel is enrolled to a UC-260, the UC-260’s light
indicator copies the status of the PgY control panel output. If an alarm
is triggered, the siren of the UC-260 sounds. Also an exit and entrance
delay can be indicated. The exit and entrance delay can be set in two
ways:
1. When a control panel is enrolled and one beep is heard, than both exit
and entrance delays will be performed regardless of the control panel’s
setting.
2. When two beeps are heard, the UC-260 copies the control panel’s
setting of the exit and entrance delays.
You can toggle between these two settings each time you enroll the
control panel to the UC-260 (entering 299 code while in the service
mode).
Alarm mode
The UC-260 can be used as a simple stand-alone wireless
alarm. This mode can be combined with the doorbell mode too.
In order to set the alarm mode enter the programming mode
first. Then press and hold both buttons of RC-11 for 3 sec. This
RC-11 will be than used for arming and disarming the alarm. You
can add more remote controls later. Up to 8 detectors, remote
controls or doorbell buttons can be used in an alarm mode.
Controlling the alarm
If you press the A button of the remote control, you will arm the
alarm. For delayed JA-60 detectors, a 15 seconds exit delay will be
allowed. Beeping can optionally indicate an exit delay.
If you press the B button of the remote control, you will disarm
the system.
If you activate a detector set to a delayed mode when the alarm
is armed, you will hear entrance delay beeping (15 sec.) first.
If the alarm is not disarmed with in this period the siren will go off
for 3 minutes. You can stop the siren by pressing the B button of the
remote control.
Exit and Entrance delay setting
Description above corresponds to a factory setting of the UC-260.
It can be changed using an enrolled RC-11 remote control while the
UC-260 is in its programming mode.
Press A button – alarm will indicate exit delay but not entrance
delay, detectors trigger a siren when the alarm is armed. (Factory
setting)
Press B button – alarm will not indicate exit and entrance delay;
detectors trigger a siren when the alarm is armed.
Press both buttons – alarm will indicate exit and entrance delay,
detectors trigger a siren when the alarm is armed and the first
enrolled detector (enrolled before RC-11) activates a chime
function.
Note: Alarm mode cannot be selected if a JA-60 or JA-65 control
panel has been enrolled.
If you need to replace batteries in a detector, it is necessary to
unplug the UC-260 first! Otherwise opening a cover of a detector
will trigger a tamper alarm.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron UC-260 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron UC-260 in the language / languages: English as an attachment in your email.

The manual is 0,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info