4. M4 – Service menu
This menu allows for the configuration of parameters which usually
stay fixed during normal operation. When the service menu is entered,
the
symbol is shown on the display. The menu contains 9 items
(they can be scrolled through by turning the knob). Each of the first 7
items corresponds to a parameter which can be configured in a
standard way (by pressing the knob, turning the knob until the desired
value is displayed, and re-pressing the knob).
The SPAN parameter allows you to configure
the hysteresis – the accuracy to which the
temperature is regulated. One of the following
accuracy ranges can be selected: ±0.1˚C,
±0.2˚C or ±0.5˚C (the factory default setting is
±0.2˚C).
Example:
If the accuracy is adjusted to ±0.5˚C and the temperature is
set to 24˚C, the thermostat switches the heating on when the
temperature drops below 23.5˚C and it switches it off if the
temperature goes above 24.5˚C. In reality the temperature scatter can
be slightly higher because of the temperature persistence of the room.
Warning: too high an accuracy can cause the heating to turn on
and off too frequently.
The t Lo parameter is the lower limit to which
the economical temperature can be set. In
addition, any drop in temperature under t Lo
causes a “heat to t Lo temperature” signal to
be transmitted.
The t Hi parameter is the upper limit to which
the Comfortable temperature can be set.
The AL Lo corresponds to the critically low
temperature. Any drop in temperature under
AL Lo causes a Panic signal to be sent to the
receiver (reporting a frost threat).
AL Hi corresponds to the critically high
temperature. Any rise in temperature above
AL Hi causes a Fire signal to be sent to the
receiver.
The Corr parameter allows for a correction of
possible temperature measurement offsets.
The range of adjustable corrections is ±1°C.
This parameter allows you to enable or
disable thermostat adaptive mode. If enabled,
the thermostat switches on in advance
according to the temperature persistence of
the heating system.
Selecting this item and pressing and holding
the knob for 5 seconds resets the thermostat
to the factory default settings.
By selecting OK and pressing the knob the
menu is escaped from.
The parameter ranges are restricted according to the following table:
Parameter Adjustment
range
Factory
default
Description
SPAN 0.1°C;0.2°C;0.5°C 0.2°C Hysteresis for
switching
t Lo +6°C to +40°C* 6°C Lower limit of
t Hi +6°C to +40°C* 40°C Upper limit of
AL Lo –9°C to +20°C 3°C Panic alarm
AL Hi +30°C to +70°C 60°C Fire alarm
Corr
±1°C
0 Correction
Auto On/OFF On Adaptive mode
+6°C to +40°C 18°C Economical
temperature
+6°C to +40°C 21°C Comfortable
temperature
* t Lo to t Hi and to must be valid ranges: t Lo must not be
greater than t Hi and
must not be greater than .
Party mode
You can put the thermostat into party mode by
briefly pressing the knob (indicated by
symbols
and together). After then the
thermostat maintains the Comfortable
temperature increased by 2°C.
Party mode terminates whenever a switch to Economy temperature
regulation occurs (whether manual or scheduled).
Displaying the set temperature
When not being handled, the thermostat shows the current
temperature in the room. If you want to display the temperature which
is set for the current time, turn the knob. The set temperature will then
flash on the display for 3 seconds.
Battery replacement
Replace the battery when the low-battery symbol is displayed (or the
thermostat stops working). If the thermostat is enrolled to the control
panel, then a low battery will be indicated by the control panel (to the
user and installer). Only use AA 1.5V alkaline batteries.
Integration into the OASiS system
The thermostat can be enrolled to a control panel as a detector.
If the temperature decreases below AL Lo a panic alarm will be
triggered = frost threat (heating failure).
If the temperature exceeds AL Hi then a fire alarm will be
triggered.
An AC-82 receiving unit has two output relays (X and Y).
Thermostats can be enrolled separately to each relay in order to
control two independent heating circuits.
To operate a heating system the Oasis control panel can also
be enrolled (sequence 299) to the same relay of the receiving unit
as the thermostat is enrolled to. A thermostat enrolled to the X relay
can be operated via the PGX programmable output, and a
thermostat enrolled to the Y relay operated via PGY. If the
programmable output of the control panel is switched on, the
thermostat maintains the programmed temperature. If the control
panel’s output is switched off the thermostat only triggers heating
if the temperature drops below t Lo.
To operate the heating, RC-80 or RC-88 remote controls can
also be enrolled to a receiving unit (AC-82). The heating can be
switched on by remote controls to heat to the desired temperature
and also switched off where it only heats when the temperature
is below t Lo.
To disable heating when windows are open JA-80M or JA-82M
detectors can also be enrolled to the same relay as the thermostat
is enrolled to. If the windows are closed it heats to the desired
temperature and if windows are open it heats only when the
temperature is below t Lo.
Up to 8 thermostats can be enrolled to a single relay. If at least
one thermostat transmits a heat command then the relay will be
switched on.
Specifications
Power supply: 1x AA 1.5 V alkaline battery
Battery lifetime typically 1 year
Temperature measurement: +6°C to +40 ˚C
Temperature accuracy: adjustable: ± 0.1, ± 0.2 or ± 0.5 ˚C
Freeze alarm (panic transmission) temperature threshold: < AL Lo
configurable from –9°C to +20°C
Fire alarm temperature threshold: > AL Hi
configurable from +30°C to +70°C
Operational frequency: 868 MHz, Oasis protocol
Operational radio range: up to 100 m (open area)
Operational temperature range: -10°C to + 70°C (low humidity)
Dimensions: 66 x 90 x 22 mm
Complies with
ETSI EN 300220, EN50130-4, EN55022, and EN 60950-1
Can be operated according to ERC REC 70-03
Jablotron Ltd. hereby declares that the TP-83 is in compliance
with the essential requirements and other relevant provisions of
Directive 1999/5/EC. The original of the conformity assessment
can be found on the web site www.jablotron.com
, Technical
Support section.
Note: Dispose of batteries safely
depending on battery type and local
regulations. Although this product
does not contain any harmful
materials we suggest you return the
product to the dealer or directly to
the manufacturer after use.
Mo
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron TP-83 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron TP-83 in the language / languages: English as an attachment in your email.

The manual is 0,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info