554893
2
Zoom out
Zoom in
Previous page
1/2
Next page
OS-360A / OS-365A outdoor siren 2 / 2 MGZ52200
Control panel wiring examples
If wired according to figure 2, the siren sounds and flashes during the
whole period of control panel alarms. The siren also provides an
acoustic confirmation of system setting/unsetting. The flashing stops
simultaneously with the sound.
JA-80K
OS-365A
01
COM
02
NC
NO
EW-C
IW
PGX
PGY
GND
A
B
+U
1k
PGX
function programmed to
ABC/AB/anything set
OK
NC/NO
FLASH
Fig. 2 Connection to the JA-80K control panel
If wired according to figure 3, the siren sounds and flashes during the
whole period of control panel alarms, with the light continuing to flash
for 30 minutes after alarm deactivation. No confirmation of system
setting/unsetting is provided, only a ready-state indication (1x flash in
every 45 sec) which is independent of the system status.
JA-82K
01
02
COM
03
04
EW
IW
PGX
PGY
GND
A
B
+U
1k
PGX
function programmed to
ABC/AB/anything set
OS-365A
OK
NC/NO
FLASH
Fig. 3 Connection to the JA-82K(R,C) control panel
If wired according to figure 4, the siren sounds and flashes during the
whole period of control panel alarms, with the light continuing to flash
for 30 minutes after alarm deactivation. Both acoustic confirmation of
system setting/unsetting and ready-state indication are provided – 1x
flash in every 45 sec, independently of the system status.
JA-65K
TMP
TMP
PGX
PGY
C
NC
NO
GND
SIR
+U
2k2
OS-365A
OK
NC/NO
FLASH
Fig. 4 Connection to the JA-65K control panel
If wired according to figure 5, the siren sounds and flashes during
power supply faults, with the sound continuing for just 3 more seconds
from the moment the power supply is restored. The flashing continues
for 30 minutes. No confirmation of system setting/unsetting and no
ready-state indication is provided.
JA-63K
OS-365A
L1
L2
COM
L3
L4
NO
NC
C
SIR
PGX
PGY
+U
GND
OK
NC/NO
FLASH
Fig. 5 A simplified two-wired siren-connection
Maintenance
The siren does not need any special maintenance. The NiCd battery
lifetime is about 3 years, depending on the working conditions.
Specialized auto-recharge mode keeps the battery in optimum state. If
the power supply (+12V and GND) is disconnected for a significantly
long period of time, then also disconnect the battery. It is
recommended to perform siren battery checking within general security
system testing – you can check the battery remotely without any direct
access to the siren.
Note: Whenever you handle any of the terminals (e.g. 12V
disconnection) disconnect the battery to avoid siren activation.
Important: An activation of the siren with a disconnected sounder
(see Fig. 1) does not cause any damage to the electronic circuits.
Instead, a high voltage is produced
on the sounder connector.
Specification
Power supply 10 to 15 V DC
Standby consumption < 50 mA / 12 V
Maximum load consumption < 800 mA /12 V
Backup battery NiCd pack 4.8 V / 1800 mAh
Lifetime approx. 3 years
Piezoelectric siren (OS-360) sound level 113 dB / 1 m
With second piezo-electric siren (ACM-OS360) 118 dB / 1 m
Electro-acoustic siren (OS-365) sound level 110 dB / 1 m
Siren timer max. 5 minutes
Flasher time alarm duration +15 minutes / 0
Resistance of the tamper loop < 70
Ω
Enclosure IP 34D
Security grade 2 EN 50131-1, CLC/TS 50131-4
Working environment class IV, outdoor general
Operational temperature -25 to +60°C
EMC EN 50130-4, EN 55022
Safety EN 60950-1
Dimensions 230 x 158 x 75 mm
Jablotron Ltd. hereby declares that the OS-360A/365A is in
compliance with the essential requirements and other
relevant provisions of Directives 2004/108/EC and
2006/95/EC. The original of the conformity assessment can
be found on the web site www.jablotron.com, Technical
Support section.
Note: The NiCd backup battery contains cadmium (Cd).
Dispose of batteries safely depending on battery type and
local regulations. Although this product does not contain any
harmful materials we suggest you return the product to the
dealer or directly to the manufacturer after use.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron OS-365A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron OS-365A in the language / languages: English as an attachment in your email.

The manual is 0,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info