3.2 Hard-wired inputs on the main board
There are hard-wired input terminals for 01-04 device addresses on the
main board. All hard-wired inputs act identically: double balanced loops which
sense loop stand-by, activation or tampering as follows:
stand-by connected to COM via a 1 k resistor (EOL resistor)
activation connected to COM via a 2k to 6k resistor
tampering connected to COM via a less than 700 resistor (short-
circuit) or connected to COM via a more than 6k resistor
(loop termination)
12 34
ON
OFF
01
02
COM
03
04
EW
IW
PGX
PGY
GND
A
B
+U
1k
1k
fig. 2 SA-200 magnetic detector connection
12 34
ON
OFF
01
02
COM
03
04
EW
IW
PGX
PGY
GND
A
B
+U
1k
1k
JA-82K control panel installation manual - 4 - MKH51103
fig. 3 JS-20 Largo detector connection
12 34
ON
OFF
01
02
COM
03
04
EW
IW
PGX
PGY
GND
A
B
+U
1k
1k
fig. 4 One-loop connection of JS-25 Combo
12 34
ON
OFF
01
02
COM
03
04
EW
IW
PGX
PGY
GND
A
B
+U
1k
1k
1k
1k
fig. 5 Two-loop connection of JS-25 Combo (01 GBS, 02 PIR)
12 34
ON
OFF
+U
GND
01
02
COM
03
04
fig. 6 Connection of multiple detectors to the inputs
The used input zone must be terminated by a 1k resistor in stand-by
state.
When connecting a trigger contact to the zone, always use a parallel
1k resistor. Thus it is possible to connect up to 5 trigger contacts in
series.
Tamper contacts should be connected in series (without resistors).
They therefore interrupt the whole loop. You can use an unlimited
amount of tamper contacts which can be combined with trigger
contacts (with parallel resistors).
The loop (input) reaction can be set. The NATURAL = delayed loop
reaction is set as the factory default.
If you enrol a wireless device to the hard-wired input address, the
corresponding terminal will be disabled (it will not affect the system).
If you do not intend to use the hard-wire input or enrol a wireless
device to its address, switch the corresponding DIP switch to the OFF
position (switch off the input).
3.3 Installation of additional hard-wire input
modules
By adding the JA-82C module it is possible to extend the amount of
inputs to fourteen. (addresses 01-14).
All hard-wire inputs behave identically: they are double balanced inputs
which are able to sense stand-by, activation and tampering and for which
examples of connection and conditions stated in Chapter 3.2 apply in full
scope.
When you install the module, relabel the terminal description with a
sticker from the module package (inputs 05-14). Insert plastic spacing posts
on the openings in the module on the connector side and insert the prepared
module to the selected position in the main board.
3.4 Radio module installation
The JA-82R radio module is installed in position 1 (see fig. 1). The
antenna is included in the JA-82R package and it should be screwed on a
plastic post (see fig. 17, pos 5). The antenna connector connects to the pins
on
the JA-82R module. The module installation enables the system to enroll
up to 50 wireless devices.
3.5 Y,X,V communicator module installation
Screw the selected communicator into position using the supplied
screws as shown in the picture fig. 17.
If y
ou are installing a GSM communicator (Y) and there is a strong GSM
signal in the place of installation, the self-adhesive antenna can be attached
directly to the bottom of the plastic box (see fig. 17). If there is a weak GSM
sig
nal we recommend using some of the available rod antennas.
If you use the combination of a GSM communicator (Y) and a telephone
line communicator (X), install the phone line communicator above the GSM
communicator using the supplied posts.
3.6 Control panel memory chip
The control panel memory chip plugs into its own socket. If you take the
memory unit from the control panel and plug it into another control panel main
board of the same type, the control panel settings (enrolled detectors, codes,
set functions, etc.) are transferred.
Notes:
communicator settings are not stored in this memory
do not plug or unplug the memory when the control panel is powered
when you take the memory unit from a damaged control panel, its
contents may be corrupted. It is therefore highly recommended to
back-up the settings in a PC using OLink software
3.7 Wired keypad connection
The control panel can be operated and programmed by a JA-81E hard-
wired keypad. A screened four-cord flat cable connecting the corresponding
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-82K OASIS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-82K OASIS in the language / languages: English as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-82K OASIS

Jablotron JA-82K OASIS User Manual - English - 23 pages

Jablotron JA-82K OASIS Additional guide - English - 1 pages

Jablotron JA-82K OASIS Installation Guide - German - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info