631261
12
Zoom out
Zoom in
Previous page
1/12
Next page
The JA-80Y GSM communicator - 12 - MFJ55304
A service technician needs only one set of login details to access
various installations. After the first system has been registered, the
installer can add (or remove) other installations to(or from) his/her
GSMLink account.
there is a demo version of remote access on www.GSMLink.cz
using www.GSMLink.cz
is free of charge
7.6. A complete list of CID reports to ARCs
A report to an ARC consists of: installation ID, event code, subsystem
number and the number of the source (device or code). In IP CID and
SMS CID, in addition to this, a time stamp is also sent as follows.
List of the CID reports
CID code Event ec
1130 / 3130 Intruder alarm – instant / restored 1 / 9
1134 / 3134 Intruder alarm – delayed / restored 2 / 9
1110 / 3110 Fire alarm / restored 3 / 9
1120 / 3120 Panic alarm / restored 4 / 9
1461 / 3461 Number of incorrect code-entries exceeded
alarm / restored
5 / 9
1140 / 3140 Alarm triggered during control panel power-up /
restored
6 / 9
1137 / 3137 Tamper alarm / no tampering 7 / 8
1144 / 3144 Device tamper alarm / no tampering 7 / 8
1406 Alarm cancelled by user 10
1401 / 3401 Unsetting / setting 12 / 11
3402 Partial setting 13
3408 Codeless complete setting 14
1354 / 3354 External communication fault / restored 15 / 16
1300 / 3300 Fault (except device) / all faults restored 17 / 18
1330 / 3330 Device fault / all faults restored 17 / 18
1301 / 3301 Mains dropout longer than 30 minutes /
restored
19, 20 / 21
1302 / 3302 Battery fault (except devices) / all battery faults
restored
22 / 23
1384 / 3384 Device battery fault / all battery faults restored 22 / 23
1306 / 3306 Switching to Service Mode / Leaving Service
mode
24 / 25
1661 / 3661 PGX ON/OFF 26
1662 / 3662 PGY ON/OFF 27
1355 Radio communication jamming present 28
1350 / 3350 Internal communication fault / restored 29 / 30
1602 Communication test 31
1138 Unconfirmed alarm 32
1351 Communication fault to ARC1 to ARC2 if
backups
1393 Annual check request 17
1551 / 3551 Communicator blocked / restored 31 only in
IP CID
List of source numbers
Source
number
Source
701 Control panel
731 Communicator
741 Wired keypad
001 - 050 Devices 01 - 50
500 Master code
599 Service code
501 - 550 Codes 01 - 50
Subsystem: 01 in all reports
In a split system, for setting and unsetting: 02 = A, 03 = B
For partial setting: 02 = A, 03 = AB
8. Technical specifications
Power 12V DC (from the control panel)
Stand-by consumption about 35 mA (depends on the GSM signal)
Max. consumption (during communication) 1 A
GSM band E-GSM / GPRS 900/1800MHz
RF output power 2 W for GSM900, 1 W for GSM1800
AUX output dry NC contact, max. 60 VDC / 100 mA
Complies with EN 50131-1, EN 50136-2-1, as:
ATS4, ATS 5 if CID protocol is used and the repeating period is set to zero
(sequence 06a0)
Security grade 2
Operating environment ( –10 to 40°C) class II
Safety EN 60950-1
EMC ETSI EN 301489-1, ETSI EN 301489-7
EN 55022, EN 50130-4
Radio transmissions ETSI EN 301419-1 and EN 301511
CLIP protocol (caller ID + SMS) ETSI EN 300 089 V3.1.1(2000-12)
Can be operated according to: ERC/DEC 98(20,21)
Jablotron Ltd. hereby declares that the JA-80Y is in compliance with
the essential requirements and other relevant provisions of Directive
1999/5/EC. The original of the conformity assessment can be found
at www.jablotron.com
, - Technical Support section
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer after use.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-80Y - GSM communicator at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-80Y - GSM communicator in the language / languages: English as an attachment in your email.

The manual is 0,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-80Y - GSM communicator

Jablotron JA-80Y - GSM communicator User Manual - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info