555057
4
Zoom out
Zoom in
Previous page
1/4
Next page
The JA-80X communicator 4 / 4 MKR51103
5. Communicator RESET
sequence 78080
To reset the communicator to its factory default settings enter:
78080
Note: Performing a RESET does not affect the voice message
recordings.
6. Specification
Dialling method DTMF
Phone line check enable / disable
Voice message phone numbers up to 4
(voice message assigned to one of the 5 alarm types)
Digital data transmission to an ARC CID
(Alarm Receiving Centre) (Contact ID)
Complies with EN 50131-1:
Security grade 2
Alarm transmission system class ATS 4
Environmental class 2 Indoor general (-10°C to + 40°C)
Further standards: EN 50136-1-1, EN 50136-2-1, ANSI C63.4,
EN 55022, EN 50130-4, EN 60950-1
Analogue interface connectivity EN 301437, TBR 21
Jablotron Ltd. hereby declares that the JA-80X is in
compliance with the essential requirements and other
relevant provisions of Directive 1999/5/.
The original of the conformity assessment can be found
on the web site www.jablotron.com
, Technical Support
section.
Note: Dispose of batteries safely depending on battery
type and local regulations. Although this product does
not contain any harmful materials we suggest you return
the product to the dealer or directly to the manufacturer
after use.
A brief list of programming sequences
Function Sequence Options / Notes Factory default
Programming telephone
numbers for voice
reporting
71 M xx…x *0 M = memory 1to 4
xx…x = tel. number (max. 16 digits)
*0 is the entry terminator
71M*0 erases memory M
M1 to M4 erased
Voice message recording 72
To be entered on the system keypad during the ringing period. (English)
Filtering reported events 73nx N = Group of event types
1 = All events
2 = Alarm triggering events
3 = Alarm cancellations
4 = Setting/Unsetting (Arming/Disarming)
5 = Faults
6 = Maintenance events only
7 = Regular (periodical) reports
x = 1 Report x = 0 No report
7311
ARC communication test 74
ARC phone numbers
75Mxx…x*0 M = 1 main ARC
M = 2 backup ARC
Both M1 and M2 erased
Installation ID for ARC
use
76xx…x*0
0000
Ringing period for remote
access
77n n = 1-8 duration in multiples of 5 seconds
n = 9 the call is answered after ringing for the second time
n = 0 the call is never answered
n = 0
Communicator RESET 78080
ARC reporting mode 791x x = 0 no reports
x = 1 backup to ARC1
x = 2 backup to ARC2
x = 3 always report
7910
Limited event-reporting 792x x = 0 limited reports for the 2
nd
tel. number
x = 1 all events reported to all numbers
7921
Telephone line
monitoring
793x x = 0 monitoring disabled
x = 1 monitoring enabled
7930
Sensitivity to signals on
the telephone line
794x x = 0 basic sensitivity
x = 1 higher sensitivity
7940
Busy – tone detection 795x x = 0 busy-tone detection disabled
x = 1 busy-tone detection enabled
7950
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-80X at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-80X in the language / languages: English as an attachment in your email.

The manual is 0,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-80X

Jablotron JA-80X User Manual - Dutch - 5 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info