554894
2
Zoom out
Zoom in
Previous page
1/2
Next page
JA-60WEB communicator -2 - MHO51104
2 Local network configuration
Within an Ethernet network (LAN, intranet, internet) every device is identified by an IP address (e.g.
192.168.250.20). The address can be either public or private (for example computers in a company
network have public IP addresses and a home computer with a connection to the internet via a web
provider has private IP address).
Before connecting the Ethernet cable the IP address must be set (manually or automatically) so as
not to be in collision with other computers in the network.
2.1 Manual setting of the IP address
Using a system keypad set a suitable IP address as given by a network supervisor. DHCP
(automatic assignment of IP addresses) must be disabled, see 3.1.
2.2 Automatically setting the IP address
Give your network supervisor the communicator’s MAC address which can be found on the label on
the bottom part of the communicator or on the package box. The supervisor will provide you with an
automatically assigned IP address. DHCP must be enabled (see 3.1.).
3 Communicator configuration
Communicator configuration can be done via the system keypad (the control panel must be in
programming mode). To exit programming mode, press the N key. The following settings should be
done in consultation with the network provider / supervisor. Default settings and backup can also be
made by Locator software, which can be found on www.jablotron.com.
3.1 Automatic assignment of IP address (DHCP)
Before attaching the communicator to the LAN network, it is necessary to determine the assignment
of IP address. If DHCP is disabled it is necessary to set parameters according to sequences 3.2, 3.3
and 3.4.
940 DHCP - automatic assignment of IP address disabled
941 DHCP - automatic assignment of IP address enabled
Factory default: 941 – automatic assignment of IP address is enabled
3.2 IP address setting
If DHCP is disabled, set the IP address by sequence:
91 xxx xxx xxx xxx
where: xxx xxx xxx xxx is the IP address
NOTE: if some of digits are not used in the IP address, they must be substituted by zeros (see example)
Example: to set the IP address 192.168.1.23 enter 91 192 168 001 023
Factory default setting: IP address 192.168.1.253
3.3 Netmask setting
If DHCP is disabled, set the subnet mask by sequence:
92 xxx xxx xxx xxx
where: xxx xxx xxx xxx is the netmask address
Example: to set Net mask 255.255.255.1 enter 92 255 255 255 001
Factory default setting: address 255.255.255.0
JA-60WEB communicator -3 - MHO51104
3.4 Gateway IP address setting
If DHCP is disabled, set the gateway IP address by sequence:
93 xxx xxx xxx xxx
where: xxx xxx xxx xxx is the IP address
Example: to set Gateway IP address 192.168.33.1 enter 93 192 168 033 001
Factory default setting: Gateway IP address 192.168.1.1
3.5 Reset to default setting
Entering 96060 will cause a return to the factory default settings, see 6 (the IP address and all unsent
data will be erased).
4 Web server remote access
All parameters of the JA-60WEB communicator can be set via an internet browser. Full support is
possible using MS Internet Explorer version 6 or higher. Setting can be done locally as well as from an
outside network (if it is enabled – please consult the network provider / supervisor).
4.1 Access to the web server
After setting has been done according to section 3 , enter the IP address of the communicator into
your web browser (for example: http://192.168.1.23), the login dialog will appear.
Factory default setting:
Name: jablotron
Password: jablotron
Note: The name and password can be customized (see 4.1.3)
By clicking on the reset button which can be found on the most pages, you will reset the
settings to their original values.
4.1.1 Panel
In the panel page the user can:
Monitor the control panel
Operate Hot keys for controlling the control panel quickly
Enter programming or operating sequences in the Sequence input field
See the status and operate the outputs (AUX1-AUX3) and see the status of the input (INP)
4.1.2 Events
To see the 127 latest events
4.1.3 Communicator
In the communicator page the user can:
Configure the network settings such as DHCP, IP address, Netmask and gateway
Set the Idle time for auto logoff, and HTTP port
Set the Function of the input (off - the status of the input will be only shown in the Panel
Page, tamper – when connected to GND, the control panel will trigger the tamper alarm)
Customize Login Name and Password
4.1.4 Control panel
This page is accessible only when the control panel is in programming mode (P). It enables full
setting of the control panel. A detailed description of the parameters can be found in the control
panel manual.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-60WEB at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-60WEB in the language / languages: English as an attachment in your email.

The manual is 0,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info