Alarm system JA-60 “COMFORT” - 27 - MDY51319
13.1. Internal structure of Contact ID protocol
The data in the CID protocol has following structure:
XXXX 18 Q XYZ 01 CCC
where XXXX is the account code of the installation, 18 is the code identification (identical for all events), Q is a number from 1 to
3, XYZ is the event number, 01 is the subsystem number, CCC event source details (see the table down the page).
possible source in JA-
60
JA-60
event no.
Q XYZ
Event description
C S c A J L d
058
1 110 Fire alarm
 
113
3 110 Fire alarm end
 
177
1 120 Panic alarm

058
1 120 Panic alarm from a detector

197
1 120 Panic alarm in the subsystem

187
3 120 End of the panic alarm

113
3 120 End of the panic alarm from a detector

198
3 120 End of the subsystem panic alarm

058
1 130 Intruder alarm in an instant zone

113
3 130 End of the intruder alarm in an instant zone

058
1 134 Intruder alarm in a delayed zone

113
3 134 End of the intruder alarm in a delayed zone

075
1 137 System tamper alarm
      
129
3 137 All system tampers OK
      
074
1 138 Wrong access code alarm

175
3 138 End of a wrong access code alarm

053
1 140 Alarm after powering of the control panel

075
1 144 Detector tamper alarm

129
3 144 All detector tampers OK

094
1 300 Failure (blown fuse in control panel or other general failure)
052
3 300 Control panel powering

148
3 300 No failure in the system
172
1 301 AC failure

173
3 301 AC switched on

054
1 302 Problem with power in an item
    
056
1 302 Back up battery failure in the control panel

057
3 302 End of the back up battery failure

055
3 302 End of the problem with power in the item
    
051
1 305 Reset

049
1 306 Entering of programming or user mode

050
3 306 End of programming or user mode

058
1 330 Subsystem alarm

167
1 354 Tel. line failure

169
1 354 Failure of communication in the digital bus

168
3 354 End of tel. line failure

170
3 354 End of a communication failure in the digital bus

174
1 355 RF jamming

176
3 355 End of RF jamming

094
1 380 Detector failure

148
3 380 End of all detector failures

094
1 381 Wireless item communication lost
  
148
3 381 Wireless item communication reestablished
  
054
1 384 Detector power problem
 
055
3 384 End of the detector power problem

026
1 401 Disarming

001
3 401 Complete arming

024
3 402 Partial (Home) arming

025
3 408 No code arming

171
1 602 Monitoring station communication testing (in 24 hr.)

Event sources specification in the Contact ID protocol:
JA-60 source mark code CCC
Wireless sensor
S
001 to 016
Controller
c
401 to 408
User code
501 to514
Control panel
C
701
Wireless siren
A
711
Sub control panel
J
721
Tel. Line
L
731
Digital bus
D
741
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-60 in the language / languages: English as an attachment in your email.

The manual is 2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron JA-60

Jablotron JA-60 Additional guide - English - 1 pages

Jablotron JA-60 User Manual - English - 6 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info