H-915 installation manual 11/5 TBT502 01
INSTALLER CODE
A default installer code 1010 is programmed into the H-915. This code is used with the [∗] [6] command to enter the
installer programming level. This code can be changed by installer.
ARMING
Enter a valid access code to arm. Arming is confirmed by the ARM LED and with one beep from the keypad's buzzer.
The system can not be armed if any zone is triggered. If you enter [∗][9] before the access code, the system will be AT
HOME armed (the interior zones will be bypassed automatically).
The system can also be armed by entering only [∗][0] if the quick arming function was enabled in the installer
programming level. If quick arming is enabled, the H-915 can be AT HOME armed by entering only the [∗] [9] command.
DISARMING
Enter a valid access code to disarm. If the "chime" jumper in the H-915K keypad is connected and you triggered
a sensor in a delay zone, the keypad buzzer will be beeping. In such a case you have only a limited amount of time
(entrance delay) to enter a valid access code. If an error is made in entering the code, press the [#] key and enter the
code again. The ARM LED will go out and keypad's buzzer confirms disarming with two beeps. If there are three beeps
as confirmation, it means that there is important information on display for you (for example alarm memory).
If an alarm is triggered while you are present and you want to stop it, enter a valid access code.