10.2. Time zone setting
To adjust the time information to local time, time zone setting is
possible. The car alarm adds/subtracts the time shift, expressed in
hours, to the GMT time (for middle Europe: +2 hours in summer time, +1
hour in winter time). This instruction is only available with the MASTER
code.
Instruction: MASTER TIME ±xy
xy is the time shift in hours -3,-2 …+1,+2 relative to GMT
`
MASTER TIME GSM
turns on automatic setting via incoming SMS.
10.3. Integrated Bluetooth module (BT)
A Bluetooth module is supplied as a built-in part of the CA-1803BT car
alarm. The module allows the car alarm to communicate with nearby devices
equipped with Bluetooth connectivity. For devices like PDAs, MBAs or
mobile phones, such communication can make use of navigation software
running on these devices. When disarmed and with the ignition key on, the
car alarm sends GPS coordinates via the BT which can be used for
navigation. The car alarm authorization code for device-pairing is 0000. The
ignition key must be on during the pairing process.
If the car stands still for more than 10 minutes, GPS data transmission
may start with a delay of up to 1 minute.
11. Internet remote access
The web site www.GSMLink.cz enables remote control (to users) and
setting (to installers) of the GSM pager.
To get internet access to an installed and powered car alarm you will
first be asked to register your car alarm on the first page. You will find a
unique registration code for your car alarm on the warranty card.
12. Central monitoring station communication
The GSM communicator allows central monitoring via GPRS data
protocol. The central monitoring station (CMS) gets arming, disarming and
alarm information. It also regularly checks the communication link to the car
after it is armed. So if anyone tries to tamper with GSM communications, it
will indicate an alarm at the CMS.
13. Additional features
13.1. Remote siren activation
You can operate the siren remotely by the SIREN instructions. These
instructions are accepted from all authorized (stored) phone numbers.
Commands are also accepted from any unknown phone number if they start
with the USER code.
Instruction Status
SIREN ON activates SIR output permanently
SIREN OFF deactivate SIR output
SIREN activates SIR output for 30 sec.
SIREN xxM
or
SIREN xxxS
xxM – is a numeric value of the
duration of SIR output activation, in
minutes
xxxS – as above, but in seconds.
13.2. LED indicator signals
LED state Meaning
OFF Disarmed
permanently ON Connecting to a GSM network or a phone call
Regular fast flashing
Alarm or an alarm memory or learn mode
Interrupted light Car was stopped (immobilization)
Flashing after ignition off GSM network is not available
Flashes after ignition on Number of enrolled remote controls
13.3. Pre-paid SIM card balance
It is recommended not to use prepaid cards in the car alarm. If you
have no other choice than prepaid cards, you can enable the CREDIT
instruction by the following sequence:
MASTER CREDIT uuu..u xx yyy zz
where: uuu…u is the provider’s code to obtain the balance
xx is the time period (in days) for regular checking
yyy is the threshold level below which the balance is
reported to the user (TEL1)
zz is the position of the first digit of the balance in the reply
SMS from the provider
After this sequence has been sent once, the GSM pager will check
the balance automatically every xx days and if the balance is lower
than yyy the user will be notified (TEL1)
If the CREDIT instruction is enabled in the above way, the user
can also obtain the current balance by the instruction CREDIT
To disable the automatic balance checking set the time period “xx” to 00.
13.4. Roaming
If you travel abroad and your SIM card supports roaming, the pager
will work there too except for the LOCATOR and CREDIT functions and
the GPRS data communication which will not be available.
13.5. Reset GSM
If you need to disconnect and then reconnect the GSM module to the GSM
network, then use the command “MASTER RESET GSM”.
This does not affect any settings and is typically used for GPRS activation or
charging up credit. This command always requires the Master code.
13.6. Service instruction
The DINFO instruction allows you to obtain current settings,
information about the quality of the GSM signal, the registration code for
GSMLink devices and some other parameters. This command always
requires the Master code.
Example of instruction: MASTER DINFO
Example of response: Car alarm reports: CA-1803A, SN:123456, SV:01,
LV:03, RK:ABCDE-12345-FG67, R:01, GSM:25, GPS:5, Time:3.2.06
11:35
CA-1803A car alarm version
SN:123456 identification number of the product
SV:01 software version
LV:03 language version
RK: ABCDE-12345-FG67 registration code for GSMLink
R:01 current Reset mode of the device
GSM:25 instant quality of GSM signal (ranging from 0 to 32 (best))
GPS:5 number of visible satelites (0-16)
14. AUX output
AUX output can be set to the following mode.
AUX busthis mode allows you to connect up to four CR-11A
modules to the bus. This enables you to extend car alarm functionality
via the power output. There are two outputs available: A and B. They
can be operated by pressing two buttons together on the key fob RC-8x
(see instructions to CR-11A), or using SMS instructions. This allows you
to operate independent heating, refrigerators, flashing lights etc.). The
car must not be immobilized by use of this module, because the output
reacts to incoming SMS instructions in every state of the car alarm, in
particular, while the car is on the run, thus possibly not under the user’s
control which could cause a traffic accident.
Instruction Status
AUXA (B) Relay switches on for 1 second
AUXA ON (OFF)
AUXB ON (OFF)
ON - Switch on permanently*
OFF – Switch off permanently*
AUXA xxM in xxxS
AUXB xxM in xxxS
xxM – numeric value of requested
duration of the relay to be switched
on, in minutes
xxxS – as above, in seconds
Example of an instruction to switch B relay on for 30 seconds:
AUXB 30S
* Maximum switch-on time is 60 minutes.
* If a relay (A or B) is switched on while arming, it will be switched off. In
addition, the A relay, when switched on, will also be switched off while
disarming.
15. The back-up battery and voltage monitoring
To handle an absence of supply voltage in the car (disconnecting the
main battery, deliberate damage etc.) the car alarm is equipped with a
BB-02 backup battery. The battery supplies the car alarm when no
supply voltage is present (for 5 hours minimum). Except for the acoustic
siren, the BB-02 backs-up all the functions of the car alarm. The car
alarm is supplied with a small current from the BB-02. Fully charging a
fully discharged battery requires 5 days. In the case of a supply voltage
outage, the BB-02 starts to generate a voltage either for the outage
duration or until it is completely discharged. While testing it or being
handled, it is possible to protect the backup battery from being
completely discharged by briefly shorting the BB-02’s terminals (the BB-
02 has to be disconnected from the power supply). This causes
disconnection of the electronics inside the back-up battery. In the case of
switch-over to BB-02 operation (after a voltage drop under 8.5V or after
complete disconnection of the battery), an SMS will be sent with
information about backup battery operation. An SMS will also be sent
after the recovery of the main power supply voltage (at least 10
minutes).
16. Emergency RESET
In the case of an emergency, when no installation MASTER code is
available, it is possible to perform an emergency RESET of the car alarm
even without the code. Such a reset causes the car alarm to be set to
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron CA-1803BT - reset 3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron CA-1803BT - reset 3 in the language / languages: English as an attachment in your email.

The manual is 0,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron CA-1803BT - reset 3

Jablotron CA-1803BT - reset 3 User Manual - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info