The AC-82 wireless relay output module MJT51202
2
sensor is triggered. In this mode up to 8 detectors can be enrolled to a single
relay (which triggers if any of the detectors is triggered), but no other kind of
device can be enrolled, only detectors.
If the same detector is enrolled to relay X in mode 4 and to relay Y in
mode 3, then relay X will work as its sensor trigger output and the relay Y as
its tamper output.
Using the AC-82 with control panel PG output signals
if the control panel is enrolled to the X relay (in mode 4 by entering 299) then
the X relay works as a control panel PGX output.
if the control panel is enrolled to the Y relay (in mode 4 by entering 299) then
the Y relay works as a control panel PGY output.
Only one control panel PG output can be enrolled to each relay. No other
transmitting devices can be enrolled to a relay already occupied by a control
panel PG output.
Using the AC-82 with TP-8x wireless thermostats
If a thermostat is enrolled to a relay (enrolled in mode 4 by connecting its
battery up), then this relay can be used to control the heating.
The enrollment of a thermostat to a relay is indicated by LED 1 for relay X
and LED 3 for relay Y.
Up to 8 thermostats can be enrolled to each relay. A relay energizes if any
of the thermostats requires the heating to be on.
Other devices can be combined with a thermostat and all be enrolled
to the same relay (a total of 8 devices, including the thermostat).
Wireless devices enrolled together with a thermostat to a single relay
can be used to determine how that relay reacts signals from the
wireless thermostat. If desired, the relay can react only to the freezing
protection signal from the thermostat to turn on the heating when the
temperature gets below about +6C, or alternatively it can react to the
thermostat signal which demands heating when the room temperature
is lower than that pre-programmed in the thermostat. The relay can be
switched between these two modes by operating the wireless devices.
If enrolled with a thermostat, the wireless devices have following
functions:
Key fob RC-8x: A pair of buttons is enrolled. Pressing one button switches
the relay to regulating the heating to the pre-programmed temperature, and
pressing the other button switches the relay to regulating the heating to +6C
to avoid freezing. Multiple key fobs can be enrolled and can also be combined
with window detectors (see below).
Window detectors: If a window is open, the relay reacts to the signals from
the JA-80M or JA-82M window detectors by switching to regulating the
heating to +6C to avoid freezing. Multiple window detectors can be enrolled
and they can be combined with key fobs too.
Control panel (CP) PG outputs: To switch the relay between regulating the
temperature to the pre-programmed temperature or to +6C, the CP PG
outputs should be programmed in the CP to have an ON/OFF function (see
the CP manual). The heating mode can then be selected from devices able to
switch the CP PG output such as the alarm system keypad, keyfob or even a
detector programmed to control the PG output. It could also be done remotely
by phone or the Internet (if a suitable communicator is used in the control
panel). Remember that PGX can only be enrolled to the X relay, and PGY to
the Y relay (see the above section), and it is not recommended to enroll key
fobs or detectors to the same relay to which thermostat(s) and PG outputs
are enrolled as the control panel repeats currently valid PG signals every 9
minutes. If you wish to combine keypad operation with keyfobs, it is best to
enroll the keyfobs to the control panel and program them to control the PG
output which is enrolled to the relevant relay.
If the relay is in the mode which regulates the heating to a pre-programmed
temperature, this is indicated by LED 1 for relay X, and LED 4 for relay Y. The
current contact status of relay X is shown by LED 2, with relay Y’s being
shown by LED 4.
The thermostat repeats its signal every 9 minutes, so if the AC-82
power is turned off for a while, and then on again, the relay will
synchronize with the thermostat within 9 minutes.
If you switch the relay to the mode for regulating the heating to the pre-
programmed temperature (e.g. by keyfob etc.), then the mode is
changed instantly, however, the relay will only switch the heating on
after the thermostat has sent an instruction to turn the heating on (i.e.
the heating system’s reaction can be delayed by up to 9 minutes after
the request has been sent).
Resetting the AC-82 unit
New AC-82 units are sold with factory-default settings (i.e. both relays
have nothing enrolled). To reset a particular relay, do the following:
Repeatedly press the X button (or the Y button for the Y relay) to
achieve the highest number LED flashes (4, or if not possible, then 3).
Then, continuously press the same button and keep pressing it until all
the LEDs flash a couple of times (= reset). Then release the button.
Inverting the relay function (to a N.C. contact)
Both relays have only normally open contacts. If a normally closed
contact function is required (e.g. to turn off an appliance if the alarm
system is armed), then you can invert the relay function as follows:
First reset the AC-82 unit.
Using button X for relay X (or button Y for relay Y) makes LED number
4 flash.
Now keep both the X and Y buttons pressed until all the LEDs flash a
couple of times.
The relay now has a normally closed contact function.
To return it to its normal function, reset the AC-82 unit.
Note: Please remember, that if a relay has a normally closed contact function,
the relay will switch off if the AC-82 power is turned off.
Technical specifications
Power supply: 230V AC/50Hz, class protection II
Consumption about 1W
Relay contact rating
resistive load max. 2,5A / 250V AC
inductive (capacitive), lamp load max. 0,5A / 250V AC
Required fuse rating max. 5A
Communication band 868 MHz, Oasis protocol
Minimum distance from transmitting devices 1 meter
Dimensions, weight: 76 x 110 x 33 mm, antenna 35 mm, 120 g
Operating environment general, indoor –10 to +40 °C
Enclosure IP40 EN 60529
Mechanical immunity IK08 EN 50102
Complies with ETSI EN 300220, EN-50130-4, EN-55022 and EN 60950-1
Can be operated according to ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the AC-82 is in
compliance with the essential requirements and other relevant provisions of
Directive
99/5/EC The original of the conformity assessment can be found
at www.jablotron.com
, Technical Support section
Note: Although this product does not contain any harmful materials we
suggest you return the product to the dealer or directly to the producer after
use.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron AC-82 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron AC-82 in the language / languages: English as an attachment in your email.

The manual is 0,09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info