522377
4
Zoom out
Zoom in
Previous page
1/8
Next page
Warning: Should the terminals/poles be wrongly connected to the load output, can units <10A (fused) be completely damaged. Each
individual component must be fused.
Pre-installation
Upon delivery is the solar charger unit installed as follows:
- Gas control active (see functions)
The above functions can be turned off at any time.
De-activate as follows:
Gas control de-activate
1. Unscrew the 2 screws on the left side (see diagram) on the solar charger unit and carefully remove the casing/lid.
2. Disconnect the jumper J6 situated to the electronic-base. The gas control is now de-activated.
Installation - Warning: Take care that the Terminals/Poles correspond!!!
The solar charger unit should be placed proximity to the battery and be sufficiently protected against the weather. Take care to place the battery
in a well ventilated place. To enable the unit to function properly, the electrical connections should face downwards. To guarantee that the unit
functions properly it must be connected to the solar generator, the lead-battery and the load.
Each part of the system-solar generator, lead battery, load and solar charger unit should have the corresponding power supply. Please check
each component before installation, when in doubt contact a Specialist! Take careful attention of the following installation instructions:
1. Connect the battery to the corresponding terminals on the solar charger unit. To prevent the wiring from overheating and power supply
reduction the use of cable/wire 2,5-4 mm² flexible is recommended. Only when a "short-circuit-protection" connection is installed, can the
battery be operated without a fuse. Otherwise must a fuse be connected to the battery +terminal/pole in order to prevent the connection to
the solar charger unit from "short-circuiting". Both components must be installed close together in the same room.
2. Connect the solar cell to the corresponding terminals on the solar charger.
3. Connect the load to the solar charger unit.
The connection-terminals pictured on the solar charger unit or see diagram (Connection/Operating-elements).
The Solar System fails to Function - possible reasons.
Battery poles: Glass fuse is melted; replace by same type.
Module terminals/poles are wrongly connected: Avoid at all costs!!!
Load terminals/poles are wrongly connected: The apparatus can be seriously damaged before the fuse blows. Batteries contain considerable
amounts of electrical energy. A short-circuit can result in a large build-up of heat leading to FIRE!!
LED
green
LED
red
During the day At night Additional note
1 OFF OFF No flow of charging current Deep discharge not active
No flow of
charging current
Module poled;
Consumer short-circuit
Check flat fuse Check flat fuse Remove cause of defect
Load does not work although fuse
o.k.
Charge control defect.
2 ON OFF Flow of charge current
Battery is charging
The green LED reduces luminous intensity
when reaching the charging limit
Strong light of green LED Charge control defect
3 OFF ON Battery empty Load disconnection active
Consumer switched off
No flow of charging current Check poles, interruption
4 ON ON Battery empty
Flow of charge current
Load is automatically switched on after
reaching the minimum charge
Specifications
Nominal voltage:
Charging current (solar cells):
max. load:
max. power use:
Temperature sensor:
Final charging voltage:
normal
gassing deactivated
temperature compensation
Over discharge disconnection:
constant
reset voltage
Gas regulation:
gassing activation voltage
final gassing voltage
temperature compensation
Fuse:
Temperature range:
Measurements:
Weight:
12/24 V
8 A
8 A
2 mA
in-built
13,7 V / 27,4 V
14,1 V / 28,2 V
-4 mA/K/cell
11,1 V / 22,2 V
12,6 V / 25,2 V
12,4 V / 24,8 V
14,5 V / 29 V
-3 mA/K/cell
10 A
-25°C - +50°C
95 x 95 x 35 mm
230 g
Subject to technical alternation. No responsibility will be taken for Printing mistakes. 05/2009
IVT Innovative Versorgungs-Technik GmbH, Dienhof 14, D-92242 Hirschau
Phone: (49) 96 22 - 719910, Fax: (49) 96 22 – 7199120 www.IVT-Hirschau.de Info@IVT-Hirschau.de
www.busse-yachtshop.de | info@busse-yachtshop.de
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for IVT 8A Solar at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of IVT 8A Solar in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info