658894
51
Zoom out
Zoom in
Previous page
1/98
Next page
TXG237
50
(R E4 Type)
FIG. 4-29: Position the upper frame (8) on top of lower
ROPS frame. Install shoulder bolts (9) at the rear
of the frame with washers (10) and nuts (11) to the
inside. Install clevis pins (12) and link pins (13) at the
front of the frame, with link pins to the inside.
NOTE: Clevis pins and link pins are each fitted with
O-ring to prevent rattling. In addition, a push-
ing bolt (14) is installed to reduce noise.
Tighten all ROPS hardware at this time, using the fol-
lowing torque chart:
TABLE 4
Location
Bolt
Diameter
Nm lb ft
ROPS frame
hinge bolts
16mm 98 to 118 72 to 87
Bracket to
upper frame
12mm 88 to 108 65 to 80
Lower ROPS
frame
16mm 196 to 230 145 to 170
EXTERNAL AUXILIARY HYDRAULICS (V Type)
Auxiliary hydraulics can be Dealer installed to operate
implement requiring external hydraulics source for op-
eration. Kits are available 2-spool (2 hydraulic circuit)
FIGS. 4-30 & 4-31: Control lever, 1, controls implement
raising or lowering when first set of remote couplers are
used. Control lever, 2, controls implement when second
set of remote couplers are used (2-spool kit only).
Control levers are spring-loaded to center neutral
position from normal raise or lower positions. Control
lever, 2, has also free flow position. Down the lever to
the lock position to get the free flow position.
Remote couplers are located at rear of the tractor,
above 3-point hitch. Coupler set, 3, corresponds with
control lever, 1, coupler set, 4, with control lever, 2.
Implement hoses must be connected to each coupler
set so when respective control lever is pulled rearward
implement raises and when pushed forward imple-
ment lowers. Male coupler tips (on implement hoses)
must be compatible with tractor couplers and must
also be inserted fully and locked into tractor couplers
to operate correctly.
CAUTION: Always lower implement to
ground, shut off engine and relieve sys-
tem pressure (by operating control levers
with engine off) before connecting or dis-
connecting implement hoses.
14
FIG. 4-29
2
1
FIG. 4-30
FIG. 4-31
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Iseki TXG237 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Iseki TXG237 in the language / languages: English as an attachment in your email.

The manual is 10,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info