Chapter 4 – Using the Control Panel
Menu Key
The Menu key allows access to any one of eleven menus. Pressing the Menu key once allows access to the rst
menu function. Pressing the Menu key twice allows access to the second menu function, and so on. If no key is
pressed for 15 seconds in a menu window, the display will revert to the main display window. Tip: If you are in a
menu window and would like to remain in the window for more than 15 seconds, keep the pkey depressed.
Enter Key
The Enter key, if pressed for 3 seconds, allows the modication of a setting. The enter mode is indicated by a
ashing cursor on the modiable setting. Pressing the Enter key again will save any entry and move the cursor to
the next modiable item in the display window. When the last modiable choice in a window is conrmed with the
Enter key, the enter mode is automatically terminated and the new settings are saved.
Filter Life LEDs: Whenever the system is on, the colour of the lter life LEDs (light emitting diodes) indicates the
state of the in di vidual lters in the system. Note: The positions of the lter life LEDs on the control panel correspond
to the actual positions of the lters within the system.
The lter life indicator LEDs signal four possible stages in the life of the lter:
1. Green: The lter is still within 80% of its estimated life span.
2. Orange: The lter is approaching the last 20% of its estimated life span.
3. Red: The lter has reached the end of its estimated life span.
4. Red blinking: The lter has passed its estimated life span and should be replaced immediately. The IQAir®
systems effectiveness is likely to have been reduced dramatically, either due to a reduction in
airow (particle lters are clogged) or a reduction in lter efciency (gas phase lter is saturated).
Fan Speed LEDs: These LEDs simulate the fan speed through the frequency of their rotation. The faster the rotation
of the fan speed LEDs, the faster the actual fan speed of the unit.
4.2 Control Panel Locking Function
The control panel can be locked to avoid tampering with the
settings. To lock or unlock the control panel keys, the Menu and the
Enter key have to be pressed down simultaneously for 3 seconds.
The acti vated locking function is indicated with a star symbol in the
control panel display. The locking function is cancelled by disrupting
the power supply.
4.3 Fan Speed and Air Delivery
The IQAir® system can be set to run at six different fan speeds which correspond to six different airow rates. Speed
1 is the lower, speed 6 the highest fan speed. The higher the fan speed, the more room air will be ltered by the
system. The high fan speed settings provide additional air cleaning power to deal with situations of elevated
pollution levels. To allow better evaluation of the systems performance at different fan speeds, the standard display
window shows not only the fan speed, but also the air delivery rate (airow). The displayed airow is factory preset
and is not measured by the system itself.
4.3.1 Regulating Fan Speed
1. When the IQAir® system is switched off (standby mode), the rst line of the
LCD display shows the model name. To switched the system on, press the
Power key on the far left of the control panel.
2. The LCD now displays the fan speed and the corresponding airow rate.
Note: The system starts at the fan speed at which it was running when it
was last used.
3. To change the fan speed, press the pkey.
Enter
Menu
HyperHEPA
V5-Cell
PreMax
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for IQAir HealthPro 250 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of IQAir HealthPro 250 in the language / languages: English as an attachment in your email.

The manual is 5,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info