7
Chapter 3 – The IQAir® System’s Components
Chapter 3 – The IQAir® System’s Components
3.1 Description of Housing Components
The IQAir® system features a modular tower design in which all important filtration and air moving components are
positioned vertically in-line, i.e. stacked on top of another. Air is drawn into the system at the base, and passes
through several filter stages to be returned to the room via the diffuser on top of the system.The housing modules
are held together by two locking arms.
• The base, with its arched design, features air intake openings on two sides.
• The Pre-Filter module 1 consists of frame 1 and the particulate Pre-Filter which is fixed inside the frame by four
filter clamps.
• The fan assembly comprises two housing modules with the centrifugal fan inside.
• The Cartridge filter module 2 consists of frame 2 and a steel base plate in which the four gas phase filter
cartridges are fixed by means of a bayonet locking system.
• The Frame 3 covers the gas phase cartridges to where the diffuser starts.
• The EvenFlow™ diffuser contains omni-directional air outlet openings.
• The handle on top of the diffuser is designed for carrying the IQAir® system.
• The locking arms hold the housing elements together. When opened, the locking arms allow easy access to all
filters.
Front view Side view
EvenFlow™ diffuser
Pre-Filter
module (1)
Fan assembly
Cartridge filter
module (2)
Frame 3
Locking arms
Base
Handle
Air intake opening
Air outlet openings