744560
13
Zoom out
Zoom in
Previous page
1/44
Next page
Energy Distribution 2015 13
CHIMNEY CONNECTOR SYSTEMS AND
CLEARANCES FROM COMBUSTIBLE
WALLS
FOR RESIDENTIAL HEATING APPLIANCES
A. Minimum 3.5in thick brick masonry all framed
into combustible wall with a minimum of 12in. brick
separation from clay liner to combustibles. The fire
clay liner shall run from outer surface of brick wall to,
but not beyond, the inner surface of chimney flue liner
and shall be firmly cemented in place.
B. Solid-insulated, listed factory-built chimney
length of the same inside diameter as the chimney
connector and having 1in. or more of insulation with a
minimum 9in. air space between the outer wall of the
chimney length and combustibles.
C. Sheet steel chimney connector, minimum 24
gauge in thickness, with a ventilated thimble, minimum
24 gauge in thickness, having two 1in. air channels,
separated from combustibles by a minimum of 6in of
glass fiber insulation. Opening shall be covered, and
thimble supported with a sheet steel support,
minimum 24 gauge in thickness.
D. Solid insulated, listed factory-built chimney
length with an inside diameter 2in. larger than the
chimney connector and having 1in. or more of
insulation, serving as a pass-through for a single wall
sheet steel chimney connector of minimum 24-gauge
thickness, with a minimum 2in. air space between the
outer wall of chimney section and combustibles.
Minimum length of chimney section shall be 12in.
chimney section spaced 1in. away from connector
using sheet steel support plates on both ends of
chimney section. Opening shall be covered, and
chimney section supported on both sides with sheet
steel supports securely fastened to wall surfaces of
minimum 24-gauge thickness. Fasteners used to
secure chimney
section shall not penetrate chimney flue liner.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Invicta Theia at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Invicta Theia in the language / languages: English as an attachment in your email.

The manual is 9,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info