744562
14
Zoom out
Zoom in
Previous page
1/44
Next page
Energy Distribution 2015 14
Figure 6 Trim and Mantle Clearances
OUTSIDE AIR SUPPLY
You can connect an outside air source as closed as
possible to this stove using an optional air dispenser.
The advantage of providing outside air directly to the
stove is that the air used by the stove for combustion
is taken from outside the residence rather than from
within the room where the stove is located.
The outside air dispenser will allow to bring sufficient
air intake to a minimum 3" (76 mm) diameter duct
(supplied by others) * which leads to the outside of the
house. When considering placement of the air
dispenser from the outside of the house, keep in mind
the need to avoid structural members of the house.
Locate the termination of the duct on the outside wall
of the home in such a manner to avoid the possibility
of obstruction by snow, leaves or other material.
Screen the termination using ¼” x ¼” mesh rodent
screen and cover it with a rain/wind proof hood (flex
pipe, outside termination, mesh, and hood supplied by
others) Contact your dealer for availability.
VENTING COMPONENTS &
CONFIGURATION REQUIREMENTS
DO NOT CONNECT THIS UNIT TO A CHIMNEY
FLUE USED BY ANOTHER APPLIANCE
Single wall connector that is at least 24 MSG or
25 MSG blued steel stovepipe.
Double wall connector (Rear pipe) which is used
with a listed, factory-built “Type HT" chimney or
with a masonry chimney to reduce clearances, is
available from several manufacturers, your dealer
can help you choose. Some air insulated
connector pipe models available are Simpson
Dura Vent DVL and Metalbestos DS. Security,
GSW, ICC and Ameritec also have acceptable
Rear connector pipe.
The chimney connector cannot pass through a
floor or ceiling, nor any attic or roof space, closet
or similar concealed space. Where venting
requires passage through a wall or partition of
combustible construction, the installation must
conform to NFPA Code 211 or CAN/CSA - B365.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Invicta Symphonia at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Invicta Symphonia in the language / languages: English as an attachment in your email.

The manual is 9,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info