694839
39
Zoom out
Zoom in
Previous page
1/48
Next page
Guidance and manufacturer's declaration - electromagnetic emissions
The device is intended for use in the electromagnetic environment
specified below. The customer or the user of these Clinical IR thermometer
should assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment
- guidance
RF emissions CISPR 11 Group 1 The device uses RF energy
only for its internal function.
Therefore, its RF emissions are
very low and are not likely to
cause any interference in nearby
electronic equipment.
RF emissions CISPR 11 Class B Complies
Harmonic emissions
IEC 61000-3-2
Not
applicable
The ME equipment is solely
battery powered.
Voltage fluctuations/
flicker emissions
IEC 61000-3-3
Not
applicable
English 39
39


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventum TMC609 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventum TMC609 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 1,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info