771739
42
Zoom out
Zoom in
Previous page
1/44
Next page
DUCT TYPE
AIR CONDITIONING SYSTEMS
• USER’S MANUAL
• ΕΓΧΕΙΡΙΔΙΟ ΧΡΗΣΗΣ
• MANUAL UTILIZATORULUI
ENGLISH | ΕΛΛΗΝΙΚΑ | ROMANA
MODELS:
V6MDI32-18WiFiR/U6MRS32-18
V5MDI32-18WiFiR/U5MRS32-18
V5MDI32-24WiFiR/U5MRS32-24
V5MDI32-36WiFiR/U5MRS32-36
V5MDI32-50WiFiR/U5MRT32-50
V5MDI32-60WiFiR/U5MRT32-60
Table of Contents
Owner’s Manual
Indoor Unit Parts and Major Functions ...
06
Manual Operations .......................................... 08
SAFETY
FIRST
Safety Precautions .......................................... 04
1
2
3
Care and Maintenance ............................. 09
a. Unit Maintenance ....................................... 09
b. How to Clean the Air Filter ....................... 09
c. Repairing Refrigerant Leaks ...................... 10
d. Preparation for Periods of Non-use ........ 10
Troubleshooting ................................. 11
a. Common Problems ........................... 11
b. Troubleshooting Tips ......................... 12
European Disposal Guidelines .............................................................. 14
4
5
6
C au t i o n: Risk of fire/
flamm able materials
WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance
and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the
person competent in the use of flammable refrigerants. For more details ,please refer to the Information on
servicing on INSTALLATION MANUAL. (This is only required for the unit adopts R32/R290 Refrigerant)
Care and Maintenance ............................. 09
a. Unit Maintenance ....................................... 09
b. How to Clean the Air Filter ....................... 09
c. Repairing Refrigerant Leaks ...................... 10
d. Preparation for Periods of Non-use ........ 10
Troubleshooting ................................. 11
a. Common Problems ........................... 11
b. Troubleshooting Tips ......................... 12
European Disposal Guidelines .............................................................. 14
4
5
6
C au t i o n: Risk of fire/
flamm able materials
WARNING: Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance
and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the
person competent in the use of flammable refrigerants. For more details ,please refer to the Information on
servicing on INSTALLATION MANUAL. (This is only required for the unit adopts R32/R290 Refrigerant)
Page 4
Thank you for purchasing this air conditioner. This manual will provide you with information on how
to operate, maintain, and troubleshoot your air conditioner. Following the instructions will ensure the
proper function and extended lifespan of your unit.
Please pay attention to the following signs:
Safety Precautions 1
Failure to observe a warning may result in death. The appliance must be
installed in accordance with national regulations.
.
Failure to observe a caution may result in injury or equipment damage.
WARNING
CAUTION
WARNING
Ask an authorized dealer to install this air
conditioner. Inappropriate installation may
cause water leakage, electric shock, or fire.
The warranty will be voided if the unit is not
installed by professionals.
If abnormal situation arises (like burning
smell), turn off the power supply and call
your dealer for instructions to avoid electric
shock, fire or injury.
DO NOT
let the indoor unit or the remote
control get wet. It may cause electric shock
or fire.
DO NOT
insert fingers, rods or other objects
into the air inlet or outlet. This may cause
injury, since the fan may be rotating at high
speeds.
DO NOT
use a flammable spray such as hair
spray, lacquer or paint near the unit. This
may cause fire or combustion.
Do not use means to accelerate the
defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room
without continuously operating ignition
sources (for example: open flames, an
operating gas appliance or an operating
electric heater).
The appliance shall be stored so as to
prevent mechanical damage from occurring.
Be aware that the refrigerants may not
contain an odour.
Compliance with national gas regulations
shall be observed.
Keep ventilation openings clear of
obstruction.
DO NOT
pierce or burn.
NOTE:
The following informations are required
for the units adopt R32/R290 Refrigerant.
A warning that the appliance shall be stored
in a well-ventilated area where the room size
corresponds to the room area as specified
for operation.
Any person who is involved with working on
or breaking into a refrigerant circuit should
hold a current valid certificate from an
industry-accredited assessment authority,
which authorises their competence to handle
refrigerants safely in accordance with an
industry recognised assessment specification.
Servicing shall only be performed as
recommended by the equipment
manufacturer. Maintenance and repair
requiring the assistance of other skilled
personnel shall be carried out under the
supervision of the person competent in the
use of flammable refrigerants.
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in order
to avoid a hazard.
Page 5
CAUTION
DO NOT touch the air outlet while the swing
flap is in motion. Fingers might get caught
or the unit may break down.
DO NOT inspect the unit by yourself. Ask an
authorized dealer to perform the inspection.
To prevent product deterioration, do not use
the air conditioner for preservation purposes
(storage of food, plants, animals, works of
art, etc.).
This appliance can be used by children aged
from 8 years and above and persons with
reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning use of
the appliance in a safe way and understand
the hazards involved. Children shall not play
with the appliance. Cleaning and user
maintenance shall not be made by children
without supervision.
DO NOT operate the air conditioner with
wet hands. It may cause electric shock.
DO NOT touch the evaporator coils inside
the indoor unit. The evaporator coils are
sharp and may cause injury.
DO NOT place items that might be affected
by moisture damage under the indoor unit.
Condensation can occur at a relative
humidity of 80%.
DO NOT
expose heat-producing appliances
to cold air or place them under the indoor
unit. This may cause incomplete combustion
or deformation of the unit due to the heat.
After long periods of usage, check the
indoor unit to see if anything is damaged. If
the indoor unit is damaged, it may fall and
cause injury.
If the air conditioner is used together with
other heating devices, thoroughly ventilate
the room to avoid oxygen deficiency.
DO NOT
climb onto or place objects on top
of the outdoor unit.
DO NOT
operate the air conditioner when
using fumigant insecticides. The chemicals
may become layered with the unit and
endanger those who are hypersensitive to
chemicals.
DO NOT
let children play with the air
conditioner.
DO NOT
operate the air conditioner in a wet
room (e.g. bathroom or laundry room). This
can cause electrical shock and cause the
product to deteriorate.
Page 6
Indoor Unit Parts And Major Functions 2
Unit Parts
Fig. 2.1
Operating Conditions
Use the system under the following temperatures for safe and effective operation. If the air
conditioner is used under different conditions, it may malfunction or become less efficient.
COOL Mode HEAT mode DRY mode
Indoor
Temperature
17-32°C
(62-90°F)
0-30°C
(32-86°F)
17-32°C
(62-90°F)
Outdoor
Temperature
0-50°C
(32-122°F)
-15-24°C
(5-76°F)
0-50°C
(32-122°F)
-15-50°C
(5-122°F)
(low temperature
cooling models)
Air outlet
Air inlet
Air filter(on some models)
Drain hose
Electric control cabinet
Refrigerant connecting pipe
Page 7
Features
Default Setting
When the air conditioner restarts after a power
failure, it will default to the factory settings
(AUTO mode, AUTO fan, 24°C (76°F)). This
may cause inconsistencies on the remote
control and unit panel. Use your remote
control to update the status.
Auto-Restart (some models)
In case of power failure, the system will
immediately stop. When power returns, the
Operation light on the indoor unit will flash. To
restart the unit, press the ON/OFF button on
the remote control. If the system has an auto
restart function, the unit will restart using the
same settings.
Energy Saving Tips
DO NOT
set the unit to excessive temperature levels.
While cooling, close the curtains to avoid direct sunlight.
Doors and windows should be kept closed to keep cool or warm air in the room.
DO NOT
place objects near the air inlet and outlet of the unit. This will reduce the efficiency of
the unit.
Set a timer and use the built-in SLEEP/ECONOMY mode if applicable.
If you dont plan to use the unit for a long time, remove the batteries from the remote control.
Clean the air filter every two weeks. A dirty filter can reduce cooling or heating efficiency.
Adjust louvers properly and avoid direct airflow.
Louver Angle Memory Function (Optional)
Some models are designed with a louver angle
memory function. When the unit restarts after a
power failure, the angle of the horizontal louvers
will automatically return to the previous position.
The angle of the horizontal louver should not be
set too small as condensation may form and drip
into the machine. To reset the louver, press the
manual button, which will reset the horizontal
louver settings.
Refrigerant Leak Detection System
(some models)
In the event of a refrigerant leak, the LCD screen
will display “EC” and the LED indicator light will
flash.
Closing curtains during heating also
helps keep the heat in
Doors and windows should be kept
closed
Page 8
Manual Operations 3
This display panel on the indoor unit can be used to operate the unit in case the remote control has
been misplaced or is out of batteries.
Fig. 3.1
MANUAL button: This button selects the mode in the following order: AUTO, FORCED COOL, OFF.
FORCED COOL mode: In FORCED COOL mode, the Operation light flashes. The system will then
turn to AUTO after it has cooled with a high wind speed for 30 minutes. The remote control will
be disabled during this operation.
OFF mode: When the panel is turned OFF, the unit turns off and the remote control is re-enabled.
Infrared receiver
Timer indicator Alarm indicator
PRE-DEF
(pre-heating/defrost)
indicator
Manual button
Operation indicator
LED display
Pagina 14
Directivele europene pentru eliminarea
deseului 6
Utilizatorii din tarile europene pot obligati sa elimine acest produs in anumite conditii. Acest
aparat contine agent frigoric si alte materiale nocive. Legea impune colectarea si tratamentul
special al acestui tip de deseu. NU ARUNCATI acest aparat impreuna cu deseul municipal.
La eliminarea acestui aparat, respectati urmatoarele aspecte:
Lasati acest aparat intr-o unitate speciala de colectare a deseurilor electronice.
La cumpararea unui aparat nou, vanzatorul va poate ridica gratuit echipamentul vechi.
Producatorul va poate ridica produsul vechi gratuit.
Puteti vinde aparatul catre rmele care se ocupa cu colectarea erului vechi.
NOTA: Aruncarea acestui aparat in padure sau alte locuri din natura, dauneaza mediului
inconjurator. Substantele nocive pot ajunge in panza freatica si in alimente.
Toate imaginile din acest manual, au scop pur informativ. Forma reala a produsului pe care l-ati
cumparat poate usor diferita insa functiile si operatiile sunt aceleasi.
Compania nu isi asuma nici o responsabilitate pentru greselile de tipar. Aspectul zic si
specicatiile tehnice se pot schimba fara o noticare prealabila datorita imbunatatirii continue a
echipamentelor noastre.
Pentru mai multe detalii, va rugam sa contactati producatorul la numarul de telefon : +30 211
300 3300, sau vanzatorul echipamentului. Toate actualizarile acestui manual vor disponibile pe
website-ul nostru si va recomandam sa vericati intotdeauna pentru aparitia unei noi versiuni.
Scanati codul QR pentru a descarca ultima versiune a manualului.
www.inventoraerconditionat.ro/biblioteca-media
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventor V6MDI32-WiFi at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventor V6MDI32-WiFi in the language / languages: English as an attachment in your email.

The manual is 3.39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info