771611
10
Zoom out
Zoom in
Previous page
1/148
Next page
Page 10
Page 10
Indoor Unit Installation 3
Indoor Unit Parts
(within indoor unit)
Drain pipe
Drain pump
Air outlet
Air inlet
Display panel
Front grille
Louver
Refrigerant pipe
Fig. 3.1
Safety Precautions
WARNING
Securely install the indoor unit on a
structure that can sustain its weight. If the
structure is too weak, the unit may fall
causing personal injury, unit and property
damage, or even death.
Install the indoor unit at a height of more
than 2.5m (8’) above the floor.
DO NOT install the indoor unit in a
bathroom or laundry room as excessive
moisture can short the unit and corrode
the wiring.
CAUTION
• Install the indoor and outdoor units, cables
and wires at least 1m (3.2’) from televisions
or radios to prevent static or image
distortion. Depending on the appliances, a
1m (3.2’) distance may not be sufficient.
If the indoor unit is installed on a metal
part of the building, it must be grounded.
Page 11
Indoor Unit Installation Instructions
NOTE: Panel installation should be done
after piping and wiring.
Step 1: Select installation location
The indoor unit should be installed in a location
that meets the following requirements:
o The unit is at least 1m (39”) from the nearest
wall.
o There is enough room for installation and
maintenance.
o There is enough room for the connecting
pipe and drainpipe.
o The ceiling is horizontal and its structure can
sustain the weight of the indoor unit.
o The air inlet and outlet are not impeded.
o The airflow can fill the entire room.
o There is no direct radiation from heaters.
CAUTION
DO NOT install the unit in the following
locations:
In areas with oil drilling or fracking
In coastal areas with high salt content in
the air
In areas with caustic gases in the air, such
as near hot springs
In areas with power fluctuations, such as
factories
In enclosed spaces, such as cabinets
In kitchens that use natural gas
In areas with strong electromagnetic waves
In areas that store flammable materials or gas
In rooms with high humidity, such as
bathrooms or laundry rooms
RECOMMENDED DISTANCES BETWEEN THE INDOOR UNIT AND THE CEILING
The distance between the mounted indoor unit and the internal ceiling should meet the following
specifications. (See Fig. 3.2)
Connecting point
of drain pipe
Connecting point of
refrigerant pipe
(liquid side)
Connecting point of
refrigerant pipe
(gas side)
Front panel
Ground
Ceiling board
>2.5m / 8.2’
60cm / 23.6” (Ceiling hole)
Ceiling
Fig. 3.2
>29cm / 11.4”
26cm / 10.2”
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventor V6MCRI32-18WiFiR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventor V6MCRI32-18WiFiR in the language / languages: English, German as an attachment in your email.

The manual is 23.21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Inventor V6MCRI32-18WiFiR

Inventor V6MCRI32-18WiFiR User Manual - English, German - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info