Outdoor Unit Installation
Outdoor Unit Installation Instructions
Step 1: Select installation location.
The outdoor unit should be installed in the
location that meets the following requirements:
o Place the outdoor unit as close to the indoor
unit as possible.
o Ensure that there is enough room for
installation and maintenance.
o The air inlet and outlet must not be
obstructed or exposed to strong wind.
o Ensure the location of the unit will not be
subject to snowdrifts, accumulation of leaves
or other seasonal debris. If possible, provide
an awning for the unit. Ensure the awning
does not obstruct airow.
o The installation area must be dry and well
ventilated.
o There must be enough room to install the
connecting pipes and cables and to access
them for maintenance.
o The area must be free of combustible gases
and chemicals.
o The pipe length between the outdoor and
indoor unit may not exceed the maximum
allowable pipe length.
o If possible, DO NOT install the unit where it
is exposed to direct sunlight.
o If possible, make sure the unit is located far
away from your neighbors’ property so that
the noise from the unit will not disturb them.
o If the location is exposed to strong winds (for
example: near a seaside), the unit must be
placed against the wall to shelter it from the
wind. If necessary, use an awning.
(See Fig. 9.1 & 9.2)
o Install the indoor and outdoor units, cables
and wires at least 1 meter from televisions or
radios to prevent static or image distortion.
Depending on the radio waves, a 1 meter
distance may not be enough to eliminate all
interference.
Strong wind
Strong wind
Strong wind
Fig. 9.1
Fig. 9.2
Step 2: Install outdoor unit.
Fix the outdoor unit with anchor bolts (M10)
>60cm / 23.6”
Fix with bolts
Be sure to remove any obstacles
that may block air circulation.
Make sure you refer to Length
Specications to ensure there is
enough room for installation and
maintenance.
Fig. 9.3
9
CAUTION
Page 27
NOTE:
The minimum distance between the
outdoor unit and walls described in the
installation guide does not apply to airtight
rooms. Be sure to keep the unit unobstructed
in at least two of the three directions (M, N, P)
(See Fig. 9.5)
Fig. 9.5
Outdoor Unit Mounting Dimensions
Rows of series installation
L H L 1/2H
L A
25 cm / 9.8” or more
1/2H < L H
30 cm / 11.8” or more
L > H Can not be installed
The relations between H, A and L
are as follows.
B
A
D
The mounting dimensions vary among different outdoor units.
The fixing bolt head diameter should be more than 12mm.
Outdoor Unit Dimentsion (mm) Mounting Dimentsion (mm)
W H DAB
952 1333 415 634 404
900 1170 350 590 378
Fig. 9.3
M
N
P
30 cm / 12” from back wall
60 cm / 24” above
30 cm / 12” on left
30 cm / 12”on right
200 cm / 79” in front
W
H
Outdoor Unit Dimentsion (mm) Mounting Dimentsion (mm)
W H DAB
681 434 285 460 292
700 550 275 450 260
300
333
363
420
555
554
702
810
770
800
845
946
487
514
540
673
298
340
350
403
Fig. 9.4
W
H
A
B
D
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventor V5MFI32-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventor V5MFI32-60 in the language / languages: English as an attachment in your email.

The manual is 20.26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Inventor V5MFI32-60

Inventor V5MFI32-60 Additional guide - English - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info