771590
27
Zoom out
Zoom in
Previous page
1/156
Next page
Page 26
DO NOT DEFORM PIPE
WHILE CUTTING
Be extra careful not to damage, dent, or
deform the pipe while cutting. This will
drastically reduce the heating efficiency
of the unit.
Step 2: Remove burrs
Burrs can affect the air-tight seal of refrigerant
piping connection. They must be completely
removed.
1.
Hold the pipe at a downward angle to prevent
burrs from falling into the pipe.
2.
Using a reamer or deburring tool, remove all
burrs from the cut section of the pipe.
Pipe
Reamer
Point down
Step 3: Flare pipe ends
Proper flaring is essential to achieve an airtight
seal.
1.
After removing burrs from cut pipe, seal
the ends with PVC tape to prevent foreign
materials from entering the pipe.
2.
Sheath the pipe with insulating material.
3.
Place flare nuts on both ends of pipe. Make
sure they are facing in the right direction,
because you can’t put them on or change
their direction after flaring. See
Fig. 5.3.
Flare nut
Copper pipe
4.
Remove PVC tape from ends of pipe when
ready to perform flaring work.
5.
Clamp flare form on the end of the pipe.
The end of the pipe must extend beyond the
edge of the flare form in accordance with the
dimensions shown in the table below.
PIPING EXTENSION BEYOND FLARE FORM
Fig. 5.2
Fig. 5.3
Fig. 5.4
Outer Diameter of
Pipe (mm)
A (mm)
Min. Max.
Ø 6.35 (Ø 0.25”) 0.7 (0.0275”) 1.3 (0.05”)
Ø 9.52 (Ø 0.375”) 1.0 (0.04”) 1.6 (0.063”)
Ø 12.7 (Ø 0.5”) 1.0 (0.04”) 1.8 (0.07”)
Ø 16 (Ø 0.63”)
Ø 19 (Ø 0.75”)
2.0 (0.078”) 2.2 (0.086”)
2.0 (0.078”) 2.4 (0.094”)
Flare form
Pipe
A
Fig. 5.5
Page 27
6.
Place flaring tool onto the form.
7.
Turn the handle of the flaring tool clockwise
until the pipe is fully flared.
8.
Remove the flaring tool and flare form, then
inspect the end of the pipe for cracks and
even flaring.
Step 4: Connect pipes
When connecting refrigerant pipes, be careful
not to use excessive torque or to deform the
piping in any way. You should first connect the
low-pressure pipe, then the high-pressure pipe.
MINIMUM BEND RADIUS
When bending connective refrigerant piping,
the minimum bending radius is 10cm. See
Fig.5.6.
≥10cm (4in)Radius
TORQUE REQUIREMENTS
Instructions for Connecting Piping
to Indoor Unit
1.
Align the center of the two pipes that you will
connect. See Fig. 5.7
.
Indoor unit tubing Flare nut Pipe
2.
Tighten the flare nut as tightly as possible by
hand.
3.
Using a spanner, grip the nut on the unit
tubing.
4.
While firmly gripping the nut on the unit
tubing, use a torque wrench to tighten the
flare nut according to the torque values in the
Torque Requirements table below. Loosen
the flaring nut slightly, then tighten again.
Fig. 5.6
Fig. 5.7
Fig. 5.8
Outer Diameter of Pipe (mm) Tightening Torque (N•cm) Add. Tightening Torque (N•cm)
Ø 6.35 (Ø 0.25”) 1,500 (11lbft) 1,600 (11.8lbft)
Ø 9.52 (Ø 0.375”) 2,500 (18.4lbft) 2,600 (19.18lbft)
Ø 12.7 (Ø 0.5”) 3,500 (25.8lb•ft) 3,600 (26.55lb•ft)
Ø 16 (Ø 0.63”)
Ø 19 (Ø 0.75”)
4,500 (33.19lb•ft)
6,500 (47.94lb•ft)
4,700 (34.67lb•ft)
6,700 (49.42lb•ft)
DO NOT USE EXCESSIVE TORQUE
Excessive force can break the nut or damage the refrigerant piping. You must not exceed
torque requirements shown in the table above.
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Inventor P9VO32 Passion Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Inventor P9VO32 Passion Eco in the language / languages: English, German as an attachment in your email.

The manual is 25.36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Inventor P9VO32 Passion Eco

Inventor P9VO32 Passion Eco Additional guide - English - 24 pages

Inventor P9VO32 Passion Eco Additional guide - English - 60 pages

Inventor P9VO32 Passion Eco User Manual - English - 76 pages

Inventor P9VO32 Passion Eco Additional guide - German - 60 pages

Inventor P9VO32 Passion Eco User Manual - German - 76 pages


The manual is sent by email. Check your email