TROUBLESHOOTING GUIDE (continued)
1
. Filter pump not attached to system
and/or switch on.
2
. Circulation line is blocked.
3
. Incorrect inlet and outlet hose direction.
4
. Scale on the flow sensor.
5
. Flow sensor cord is loose.
6
. Inner timer conflict between filter pump
and Ozone & Saltwater system.
7
. Flow sensor failure.
1
. Dirt or scale on titanium plates.
2
. Low salt level / No salt.
3
. Electrolytic cell cord is loose.
4
. Possible electrolytic cell failure.
1
. High salt level.
1
. LED display is off and the “SERVICE”
light is on - the system does not power
up.
2
. Caused by high humidity.
3
. PCB failure.
1
. Ozone generator assembly failure.
Ensure filter pump is attached and operating.
See "Setup Instruction".
If your unit has plunger valves, ensure that
they are open.
Clear your filter cartridge and cell from debris
and dirt. See “Maintenance”.
Release all trapped air in the circulation line.
See the filter pump manual.
Check the direction of the inlet and the outlet
hose. Reverse the hoses if necessary. See
“Set Up Instructions”.
Clean the flow sensor, paying special attention
to the hinge. See “Maintenance”.
Plug the flow sensor firmly into the flow sensor receptacle.
Reset both timers on the filter pump and
Ozone & Saltwater System.
Contact Intex Service Center.
Remove the electrolytic cell for inspection.
Clean it if necessary. See “Maintenance”.
Add salt. See “Salt & Pool Water Volumes”.
Ensure that the cell cord is plugged firmly into
the cell housing receptacle.
Contact Intex Service Center. Replace the cell if needed.
Partially drain the pool and refill it with fresh
water. See “Salt & Pool Water Volumes”.
Household voltage is too high or too low (+ 20%).
Check the voltage is within the range stated on the
device housing.
Run the system during midday and avoid running it
during dawn, foggy or raining time. Place a piece of
tile or similar pad, 15”x15” (38x38 cm) in size,
between the device and the ground to keep ground
water evaporation away from the system.
Contact Intex Service Center.
Contact Intex Service Center.
LED PANEL
CODE
PROBLEM
SOLUTION
LED Panel Code Flash & Alarm On (
NOTE:
Always turn off the power before cleaning and servicing).
21


Need help? Post your question in this forum.

Forumrules
1

Forum

intex-zs6110-krystal-clear

Reset search

  • How do I take the cover off to get to the motherboard?
    Submitted Submitted on 7-7-2022 at 21:39

    Reply Report abuse
  • How do I take the cover off to get to the motherboard? Submitted on 20-6-2022 at 03:33

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex ZS6110 Krystal Clear at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex ZS6110 Krystal Clear in the language / languages: English as an attachment in your email.

The manual is 2,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info