686608
15
Zoom out
Zoom in
Previous page
1/23
Next page
342A
SAVE THESE INSTRUCTIONS
(342IO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/11/2018
English
Page 15
Initial startup and operation:
Before operating, be sure that:
All the hoses have been connected and tightened securely, and correct amount of filter sand
have been loaded.
The entire system is connected to a grounding type receptacle protected by a ground-fault
circuit interrupter (GFCI) or residual current device (RCD).
OPERATING INSTRUCTIONS (continued)
CAUTION
The filter control valve has a closed position. The pump should never
be on when the valve is in the closed position. If the pump is operated
with the valve closed, explosive situation could exist.
1.
Turn both plunger valve handles fully counter-clockwise until they stop. This opens the valves to
allow water to flow into the sand filter pump. With water flowing into sand filter pump, the water
pressure will allow the air trapped inside to escape from the air release valves
(19)
. When all the
air has escaped water will flow out of the valves
(19)
. When this occurs gently finger tighten the
valves
(19)
in a clockwise direction.
IMPORTANT: To prevent air lock, open the lower plunger valve (connected inlet hose) first
and then the upper plunger valve (connected outlet hose). Open the air release valves, wait
until water starts to flow out of the air release valves, close air release valves.
2.
Ensure the drain/waste outlet on the 6-way valve is not covered and directed to a proper draining
receptacle.
3.
BACKWASH
- Ensure the pump is off, depress the 6-way valve
and turn it to the “
BACKWASH
” position
(see drawings 24 & 29)
.
IMPORTANT: To prevent damage to the 6-way valve, always
depress the valve handle before turning. Always switch off
pump before changing the 6-way valve position.
4.
Press
to switch on the system, and then press to set
the operating TIMER hours (see “Operating the system under
TIMER mode or manually” section for details). Water is circulating
backward through the sand media and to waste/drain outlet.
Backwash until a clear flow of water is observed in the waste/
drain outlet or through the drain sediment window.
NOTE:
If the LED display flashes “00”, the device is in stand-by mode and the pump will not
operate. The initial backwash of the filter is recommended to remove any impurities or fine sand
particles in the sand media.
5.
Switch off the pump, change the 6-way valve to “RINSE” position
(see drawing 25)
.
6.
Switch on the pump and run the pump for about one minute to level out the sand bed after
backwashing the sand media.
7.
Switch off the pump, change the 6-way valve to “FILTER” position
(see drawing 23)
.
8.
Switch on the pump. The system is now operating in the normal filtering mode. Run the pump
until the desired pool water clearance is obtained and no more than 12 hours per day. For the
initial startup, it is recommended setting the system to a longer TIMER operating hours or “FP” for
the pump to operate continuously without the TIMER.
9.
Record the initial pressure gauge reading when the filter media is clean.
NOTE:
During initial setup of the system, it may be necessary to backwash frequently due to
unusual heavy dirt present in the water and sand. After that, as the filter removes dirt and
impurities from the pool water, the accumulated dirt in the sand media will cause the pressure
to rise and the flow to diminish. If there is no vacuuming device attached to the system and
the pressure gauge reading is in the yellow zone it is time to backwash the sand media, see
“BACKWASH” under “initial startup and operation” section.
Vacuuming device (i.e. Intex auto pool cleaner) attached to the system may also cause the
flow to diminish and the pressure to rise. Remove any vacuuming device from the system and
check if the pressure gauge reading has dropped from the yellow zone to the green zone.
10.
Monitor the pressure gauge reading, and check that the inlet and outlet openings are not
obstructed on a weekly basis. If the pressure gauge indicates yellow it is time to backwash the
filter media.
29
1
2
15


Need help? Post your question in this forum.

Forumrules
1

Forum

intex-sf70220-2

Reset search

  • Bonjour,
    Ma pompe fonctionne parfaitement
    Je la coupe via le bouton on off.
    Je veux la redémarrer toujours via le on off
    Elle ne demmare plus...elle fait bip bip ...
    Et je n'ai plus que le petit point sur l'écran.
    Submitted on 19-6-2022 at 15:40

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex SF70220-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex SF70220-2 in the language / languages: English as an attachment in your email.

The manual is 6,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intex SF70220-2

Intex SF70220-2 User Manual - German - 23 pages

Intex SF70220-2 User Manual - French - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info