686148
14
Zoom out
Zoom in
Previous page
1/24
Next page
342
PO
SAVE THESE INSTRUCTIONS
(342PO) SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/08/2018
English
Page 14
OPERATING INSTRUCTIONS
Valve Position
Function Water Flow Direction
FILTER
(see drawing 23)
Normal filtration and regular
vacuuming of pool
From pump through filter media to
pool
BACKWASH
(see drawing 24)
Reverses water flow to clean filter
media
From pump through filter media to
valve waste/drain outlet
RINSE
(see drawing 25)
For initial startup cleaning of the sand, and
leveling the sand bed after backwashing
From pump through filter media to
valve waste/drain outlet
WASTE
(see drawing 26)
For vacuuming directly to waste,
lowering pool level or to drain the pool
From pump to valve waste/drain
outlet bypassing the filter media
RECIRCULATE
(see drawing 27)
For circulating water back to pool
without going through the filter media
From pump through valve to pool
bypassing the filter media
CLOSED
(see drawing 28)
Shuts off all flow to filter and pool
“Do not use this setting with pump running”
6-way valve positions and function:
Risk of electric shock. Connect this product only to a grounding type receptacle protected
by a ground-fault circuit interrupter (GFCI) or residual current device (RCD). Contact a
qualified electrician if you cannot verify that the receptacle is protected by a GFCI/RCD.
Use a qualified electrician to install the GFCI/RCD, which has a maximum rate of 30 mA.
Do not use a portable residual current device (PRCD).
To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or
converter plugs to connect unit to electric supply; provide a properly located outlet.
Do not attempt to plug in or unplug this product while standing in water or when your
hands are wet.
Never operate this product above the maximum working pressure stated on the filter tank.
Always switch off pump before changing the 6-way valve position.
Operating this product without water flowing through the system can cause a build up of
hazardous pressure which can result in an explosive situation, serious injury, property
damage or death.
Never test this pump with compressed air. Never operate the system with water
temperature above 35°C (95°F).
WARNING
RE
T
L
I
F
E
S
N
I
R
ET
A
L
U
C
RI
C
E
R
E
S
O
LC
ETSA
W
B
23
E
SN
IR
ETALU
C
RICER
HSAW
K
C
A
B
E
S
O
LC
E
TSAW
24
RE
TLI
F
ES
N
IR
E
TALU
C
RICER
H
SAWKCAB
ETSA
W
25
R
E
T
LI
F
E
S
NI
R
ER
H
S
AW
K
CA
B
ESO
L
C
ETSAW
26
R
E
T
LIF
ESN
I
R
E
TA
L
U
C
R
I
CE
R
H
S
A
W
K
C
A
B
E
S
O
L
C
27
R
E
TL
I
F
ETALUC
R
ICER
H
S
AWK
CA
B
ES
O
LC
ETSAW
28
Control panel description:
ON / OFF button LOCK / UNLOCK button TIMER button
LED Reading Definition
00 Stand-by mode (start-up / operating cycle finished)
01 Minimum operating hour (1 hour remaining)
02-11 Operating hours (2 - 11 hours remaining)
12 Maximum operating hours (12 hours remaining)
FP Timer OFF (pump operating continuously)
Power saving mode
.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex SF70110 Krystal Clear at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex SF70110 Krystal Clear in the language / languages: English as an attachment in your email.

The manual is 5,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info