686018
5
Zoom out
Zoom in
Previous page
1/19
Next page
315
PO
SAVE THESE INSTRUCTIONS
English
(315PO) PRISM FRAME
TM
POOL ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2016
Page 5
Barriers for Residential Swimming Pool Guidelines:
An outdoor swimming pool, including an inground, aboveground, or onground pool, hot tub, or spa, should be
provided with a barrier which complies with the following:
1.
Thetopofthebarriershouldbeatleast48inchesabovegrademeasuredonthesideofthebarrierwhich
faces away from the swimming pool. The maximum vertical clearance between grade and the bottom of
the barrier should be 4 inches measured on the side of the barrier which faces away from the swimming
pool.Wherethetopofthepoolstructureisabovegrade,suchasanabovegroundpool,thebarriermay
beatgroundlevel,suchasthepoolstructure,ormountedontopofthepoolstructure.Wherethebarrieris
mounted on top of the pool structure, the maximum vertical clearance between the top of the pool structure
and the bottom of the barrier should be 4 inches.
2.
Openings in the barrier should not allow passage of a 4-inch diameter sphere.
3.
Solidbarriers,whichdonothaveopenings,suchasamasonryorstonewall,shouldnotcontain
indentations or protrusions except for normal construction tolerances and tooled masonry joints.
4.
Wherethebarrieriscomposedofhorizontalandverticalmembersandthedistancebetweenthetopsofthe
horizontalmembersislessthan45inches,thehorizontalmembersshouldbelocatedontheswimmingpool
sideofthefence.Spacingbetweenverticalmembersshouldnotexceed1-3/4inchesinwidth.Wherethere
are decorative cutouts, spacing within the cutouts should not exceed 1-3/4 inches in width.
5.
Wherethebarrieriscomposedofhorizontalandverticalmembersandthedistancebetweenthetopsof
thehorizontalmembersis45inchesormore,spacingbetweenverticalmembersshouldnotexceed4
inches.Wheretherearedecorativecutouts,spacingwithinthecutoutsshouldnotexceed1-3/4inchesin
width.
6.
Maximummeshsizeforchainlinkfencesshouldnotexceed
1-1/4
inch square unless the fence is provided
with slats fastened at the top or the bottom which reduce the openings to no more than 1-3/4 inches.
7.
Wherethebarrieriscomposedofdiagonalmembers,suchasalatticefence,themaximumopeningformed
by the diagonal members should be no more than 1-3/4 inches.
8.
AccessgatestothepoolshouldcomplywithSectionI,Paragraphs1through7,andshouldbeequipped
to accommodate a locking device. Pedestrian access gates should open outward, away from the pool, and
shouldbeself-closingandhaveaselflatchingdevice.Gatesotherthanpedestrianaccessgatesshould
haveaself-latchingdevice.Wherethereleasemechanismoftheself-latchingdeviceislocatedlessthan54
inchesfromthebottomofthegate,(a)thereleasemechanismshouldbelocatedonthepoolsideofthe
gateatleast3inchesbelowthetopofthegateand(b)thegateandbarriershouldhavenoopeninggreater
than1/2inchwithin18inchesofthereleasemechanism.
9.
Whereawallofadwellingservesaspartofthebarrier,oneofthefollowingshouldapply:
(a)
All doors with direct access to the pool through that wall should be equipped with an alarm which
produces an audible warning when the door and its screen, if present, are opened. The alarm should
sound continuously for a minimum of 30 seconds within 7 seconds after the door is opened. Alarms
shouldmeettherequirementsofUL2017General-PurposeSignalingDevicesandSystems,
Section77.Thealarmshouldhaveaminimumsoundpressureratingof85dBAat10feetandthe
sound of the alarm should be distinctive from other household sounds, such as smoke alarms,
telephones, and door bells. The alarm should automatically reset under all conditions. The alarm should
be equipped with manual means, such as touchpads or switches, to temporarily deactivate the alarm for
asingleopeningofthedoorfromeitherdirection.Suchdeactivationshouldlastfornomorethan15
seconds. The deactivation touchpads or switches should be located at least 54 inches above the
threshold of the door.
(b)
ThepoolshouldbeequippedwithapowersafetycoverwhichcomplieswithASTMF1346-91listed
below.
(c)
Other means of protection, such as self-closing doors with self-latching devices, are acceptable so long
asthedegreeofprotectionaffordedisnotlessthantheprotectionaffordedby(a)or(b)described
above.
10.
Whereanabovegroundpoolstructureisusedasabarrierorwherethebarrierismountedontopofthe
poolstructure,andthemeansofaccessisaladderorsteps,then(a)theladdertothepoolorsteps
shouldbecapableofbeingsecured,lockedorremovedtopreventaccess,or(b)theladderorsteps
shouldbesurroundedbyabarrier.Whentheladderorstepsaresecured,locked,orremoved,any
opening created should not allow the passage of a 4-inch diameter sphere.
Barriers should be located so as to prohibit permanent structures, equipment or similar objects from being
used to climb the barriers.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex Prism Frame - 26712NP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex Prism Frame - 26712NP in the language / languages: English as an attachment in your email.

The manual is 2,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intex Prism Frame - 26712NP

Intex Prism Frame - 26712NP User Manual - German - 13 pages

Intex Prism Frame - 26712NP User Manual - Dutch - 14 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info