(187IO) MODEL ZS8220 & ZS8230 OZONE & SALTWATER SYSTEM ENGLISH 7.5” X 10.3” PANTONE 295U 08/01/2012
187A
SAVE THESE INSTRUCTIONS Page 21
English
MAINTENANCE
MAINTENANCE (continued)
The 3-Way Test Strips can test the “Free Chlorine”, “pH”, and “Total Alkalinity”
levels at the same time. We recommend that you test the water chemistry weekly,
and maintain the chlorine concentration at 0.5-3 ppm.
Directions and Use
1. Dip the entire strip into the water and remove immediately.
2. Hold the strip level for 15 seconds. Do not shake excess water from the strip.
3. Now compare the strip pad to the color chart on the packaging label. If
necessary, adjust the chemical level in the pool water. It is very important, to
use the proper technique when testing the water's chemical level. Read and
follow the written strip instructions carefully.
1. Disconnect the power cord from the electrical outlet.
2. After the pool is completely empty, disconnect the Ozone & Saltwater System
from the hoses by reversing the installation instructions.
3. Air-dry the unit before you store it. This might be a good time to visually inspect
and clean the electrolytic cell.
4. Store the unit and accessories in a dry place. The temperature should be
controlled, between 32 degrees Fahrenheit (0 degrees Celsius) and 97
degrees Fahrenheit (36 degrees Celsius).
5. The original package can be used for storage.
INTEX
®
3-WAY TEST STRIPS (PACKED WITH THE PRODUCT)
LONG TERM STORAGE
4. In a counter-clockwise motion, unscrew the Titanium electrode nut (4). Pull out
the Titanium electrode (5).
5. Pour kitchen grade vinegar into a mug to immerse the titanium plates. Soak
them for about one hour and then flush with a garden hose.
6. Reverse steps 3 and 4 to replace the Titanium electrode (5).
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex Krystal Clear Ozon Saltwater Systeem ZS8230 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex Krystal Clear Ozon Saltwater Systeem ZS8230 in the language / languages: English as an attachment in your email.

The manual is 2,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intex Krystal Clear Ozon Saltwater Systeem ZS8230

Intex Krystal Clear Ozon Saltwater Systeem ZS8230 User Manual - German - 23 pages

Intex Krystal Clear Ozon Saltwater Systeem ZS8230 User Manual - Dutch - 27 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info