OPERATION INSTRUCTIONS (continued)
6. Boost cycle
First time installation, press and hold “BOOST” button for 5 seconds until
the indicator lights up and the LED display “80”. This indicates that the
saltwater system has started more chlorine sanitizer production. You can
press and hold the “BOOST” button for another 5 seconds until the indicator
is off, which will cancel the Boost cycle.
The boost operating hours is 8 times the amount of time programmed into the
system, i.e. if your saltwater system operating time is 2 hours, the boost procedure will run 8 x 2 =
16 hours. After boost procedure has been completed, the system will automatically switch to
the normal working mode.
Once the boost is operating, check whether the filter pump operating hours have been set
properly. For example, the boost operating time is 8 hours, the filter pump should be set to
run for 8 hours at least. Increase the filter pump operating time if necessary.
NOTE: If an Intex filter pump is attached to the system, set the pump switch to on “I”
position.
After a heavy rain or if the pool is dirty, press the “BOOST” button to shock
the pool again.
7. Stand-by/power saving mode:
When the cycle ends, the green “SLEEP” indicator on the control panel
lights up and the LED display flashes “93”. The system is now in Stand-By
mode. After a while, it shuts down and sets itself in a Power Saving mode.
The system will automatically turn itself back on in 24 hours,
starting its daily cycle of chlorine production.
The “SLEEP” indicator stays on, while the system is in the Power Saving
mode. The LED display however, goes blank after 5 minutes. Press any
button ( or ) to view the last LED code.
8. Electrode Self-Clean cycle:
Press and hold button for 5 seconds until the LED display flashes
“10”. Depending on your pool water calcium hardness level, press
button again to select the self-clean cycle time as below. Total of 3
settings: 14 hours, 10 hours and 06 hours.
NOTE: The life of the cell varies depending on water conditions, pool usage and operating
time of the device. Select 14 hours cycle time to maximize the life of the electrolytic cell if
the calcium hardness level is up to 150 ppm. Manual routine cleaning and maintenance will
further lengthen the life of the electrolytic cell.
With the desired self-clean hours showing, press button to lock the keypad controls and
the LED display will return to the normal operating time. The system will reverse the polarity
of the electrode (5) every time according to the selected hours.
NOTE: If you forget to lock the keypad controls, the system will automatically lock it.
Calcium Hardness Self-clean cycle time
0 - 150 ppm Reverse polarity every 14 hours
150 - 250 ppm Reverse polarity every 10 hours
250 - 350 ppm Reverse polarity every 06 hours
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex ECO5230 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex ECO5230 in the language / languages: English as an attachment in your email.

The manual is 0,95 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intex ECO5230

Intex ECO5230 User Manual - German - 28 pages

Intex ECO5230 User Manual - Dutch - 29 pages

Intex ECO5230 User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info