(189IO) MODEL CS7221/CS7231 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 07/11/2012
189A
SAVE THESE INSTRUCTIONS
English
Page 21
SALTWATER SYSTEM OPERATION (continued)
OPERATING INSTRUCTIONS
6. Boost cycle
If the test result is below 0.1ppm, press and hold “BOOST”
button for 5 seconds until the indicator lights up and the
LED display display “80”. This indicates that the saltwater
system has started copper ion and more chlorine sanitizer
production.
You can press and hold the “BOOST” button for another 5
seconds until the indicator is off, which will cancel the Boost
cycle.
Note: Once the system has started copper ion and more chlorine sanitizer
production, the boost button can’t be re-set until the power switch is off.
The boost operating hours is 8 times the amount of time programmed into the
system, i.e. if your saltwater system operating time is 2 hours, the boost procedure
will run 8 x 2 = 16 hours. After boost procedure has been completed, the system
will automatically switch to the normal working mode.
After a heavy rain or if the pool is dirty, press the “BOOST” button to shock the
pool again.
7. Test pool water regularly:
Once the copper level appears to be balanced, test the pool water every week
to maintain the proper sanitizer level.
It’s very important that the free chlorine is between 0.5-3.0 ppm and copper
ion concentration is between 0.1~0.2 ppm. When the copper level is below 0.1
ppm, repeat step 6.
NOTE: A High copper ion concentration may cause blonde hair to exhibit a
green hair. To prevent this, wear a swimming cap during swimming, and wash
hair with special shampoo after using the pool.
See “Troubleshooting Guide”.
8. Stand-by/power saving mode:
When the cycle ends, the green “SLEEP” indicator on the
control panel lights up and the LED display flashes “93”.
The system is now in Stand-By mode. After a while, it
shuts down and sets itself in a Power Saving mode. The
system will automatically turn itself back on in 24 hours,
starting its daily cycle of chlorine production.
The “SLEEP” indicator stays on, while the system is in the
Power Saving mode. The LED display however, goes blank
after 1 hour. Press any button ( or ) to view the last LED
code.
9. Running the pump alone without the Saltwater System:
To run the pump alone without the Saltwater System function,
press and hold both and buttons until you hear a “beep”,
the LED display will show “FP”. The pump is now operating
alone. NOTE: The pump cannot be operated alone under an
automatic timer mode. To stop the pump, manually turn
the switch OFF.
IMPORTANT: To keep the initial automatic operating cycle
setting of the Saltwater System, turn the switch ON, the LED
display will show “FP”, and then press until you hear a
“beep”. The LED display will now show the initial input hours
and the Saltwater System cycle will repeat again.
Downloaded from www.Manualslib.com manuals search engine
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex CS7231 Krystal Clear at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex CS7231 Krystal Clear in the language / languages: English as an attachment in your email.

The manual is 6,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intex CS7231 Krystal Clear

Intex CS7231 Krystal Clear User Manual - German - 33 pages

Intex CS7231 Krystal Clear User Manual - Dutch - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info