are displayed, if we are in a charts level contained in the C-CARD the next four
charts level are displayed.
Value-Added Data : Sets On/Off the displaying of the Value Added Data. The Value Added Data
(VAD) is a collection of additional cartographic objects which are not present on
the original paper chart (from which the electronic chart derives). These objects
have been obtained from other sources (that C-MAP believes to be reliable) and
then merged to the electronic charts in order to provide more information useful
for the navigation. VAD object can be any cartographic objects and it can be
distinguished from the official-chart-objects from the Quick Info. A dedicated
icon is shown on the Quick Info window to indicate that the object queried is a
VAD. The same icon is also shown on the Full Info page and in addition the
extended text Value Added Data is shown on the details of the VAD object.
Chart Lock (*) : Sets On/Off the Chart Lock option. When Chart Lock is On, the available zoom
scales are only the ones containing cartographic data. Instead when Chart Lock
is Off, it is possible to zoom down into zoom scales not covered by cartographic
data after the last available zoom scale covered by cartographic data. The DSI
window, if present, will show “NO CHART”, when an empty level is entered in
the location of map expansion mode.
NOTE* When an empty level is entered, the message “No cartographic coverage” is
shown on a window in a corner of the map display. The warning message is
always displayed as long as the current zoom has no data coverage.
Underwater Objects Settings
To control the display on the Underwater Objects.
Underwater Objects : Selects the max depth value to display Underwater Objects. If value is set to
Limit 0 Mt, the Underwater Objects are not shown on the charts. Menu options are
grayed out. If value is more than 0 Mt (i.e. 10 Mt), in the Range from 0 Mt to
the selected value the Underwater Objects are displayed according to their
setting below.
Rocks : Sets Off/Icon/Icon+Depth* the displaying of the Rocks.
Obstructions :Sets Off/Icon/Icon+Depth* the displaying of the Obstructions.
Diffusers : Sets Off/Icon/Icon+Depth* the displaying of Diffusers.
Wrecks : Sets Off/Icon/Icon+Depth* the displaying of Wrecks.
NOTE* Choose the options: OFF (the object is not visible independently of the
selected “Underwater Object Depth Value”); ICON (the object icon is visible
without tags, in the range selected from “Underwater Object Depth Value”
option); ICON+DEPTH (the object icon and tag is visible, in the range selected
from “Underwater Object Depth Value” option).
4.3 GENERAL DISPLAY
To set the general settings:
[MENU] + "SETUP" + [ENTER] + "GENERAL DISPLAY" + [ENTER]
Look Ahead : Allows, when it is On and Home mode is set, to place map on the screen related
to the fix position and direction, so the map shown is that before the ship.
Orient. Resolution :Sets the resolution angle for the Map Orientation, in the range [30, 60] degrees.
Time Reference :Allows switching the Time Reference between UTC or local time, by entering the
Local Time offset.
Time Format : Selects the format for the time between 12 and 24 hours.
Date Format : Selects the Date Format between MM-DD-YY (month-day-year) and DD-MM-
YY (day-month-year).
Time Line :The Time Line is a graphical indication of the direction in which the Vessel is
heading. The Time Line origin is the vessel’s position so the time line movement
is synchronized with the vessels Icon. Time Line course is given by the value
of COG (Course Over Ground) and its length is proportional to the SOG (Speed
Over Ground). It is possible to select the desired value among Off/2/10/30 Min/
1/2 hours/Infinite.
User Points : Object you place on the chart identified by its coordinates and displayed on the
screen with a reference symbol (see Mark, Waypoint). It is possible to select the
mode of display the User Point on the screen among Hidden, Icon or Visible.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Interphase CHART MASTER 11 CV plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Interphase CHART MASTER 11 CV plus in the language / languages: English as an attachment in your email.

The manual is 5,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info