531634
33
Zoom out
Zoom in
Previous page
1/44
Next page
ACV Belgium
33
7.8 Gas-luchtregeling
De gas-/luchtregeling is in de fabriek ingesteld en behoeft in principe geen aanpassingen.
De afstelling kan gecontroleerd worden door het CO
2
percentage in de verbrandingsgassen
te meten.
Gassoort Aardgas H Aardgas L
Gascategorie H / E
G20
20mBar
2L
G25
25mBar
CO
2
% op Laagstand (L)
(service en -) met open mantel
8,9
±0,1
7.6
±0,1
CO
2
% op Hoogstand (H)
(service en +) met open mantel
9,1
–0,1/+0,2
7.8
–0,1/+0,2
Gasvoordruk (mBar) 17-25 20-30
Ø gasdoseerring (mm) 7,05 7.05
Minimaal toerental (% van max) (parameter d) 25 25
Min. start toerental (% van max) (parameter F) 70 70
Gassoort Propaan P
Gascategorie 3P
G31(propaan)
37mBar
CO
2
% op Laagstand (L)
(service en -) met open mantel
9,9
±0,1
CO
2
% op Hoogstand (H)
(service en +) met open mantel
10,3
–0,3/+0,4
Gasvoordruk (mBar) 30-50
Ø gasdoseerring (mm) 5,35
Minimaal toerental (% van max) (parameter d) 40
Min. start toerental (% van max) (parameter F) 50
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intergas Comfort Line HR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intergas Comfort Line HR in the language / languages: Dutch as an attachment in your email.

The manual is 2,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intergas Comfort Line HR

Intergas Comfort Line HR Installation Guide - Dutch - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info