35
8.2 Overige storingen
8.2.1 Brander ontsteekt niet
Mogelijke oorzaken: Oplossing:
Gaskraan is dicht. Ja
Zet gaskraan open.
Nee
Lucht in de gasleiding. Ja Ontlucht de gasleiding.
Nee
Voordruk te laag. Ja Neem contact op met het gasbedrijf.
Nee
Geen ontsteking. Ja
Vervang ontsteekpen.
Nee
Geen vonk. Ontsteekunit op gasblok defect. Ja
Controleer de bekabeling. Controleer de bougiedop. Vervang de
ontsteekunit.
Nee
Gas-luchtregeling niet goed ingeregeld Ja
Neem contact op met uw leverancier.
Nee
Ventilator defect. Ja
Controleer de bedrading. Controleer de zekering. Vervang
eventueel de ventilator.
Nee
Ventilator vervuild. Ja
Reinig de ventilator.
Nee
Gasblok defect. Ja
Neem contact op met uw leverancier.
8.2.2 Brander ontsteekt luidruchtig
Mogelijke oorzaken: Oplossing:
Voordruk te hoog. Ja
Mogelijk is de huisdrukschakelaar defect. Neem contact op met
het gasbedrijf
Nee
Onjuiste ontsteekafstand. Ja
Vervang de ontsteekpen.
Controleer de ontsteekpenafstand.
Nee
Gas-luchtregeling niet goed ingeregeld. Ja
Neem contact op met uw leverancier.
Nee
Zwakke vonk. Ja
Controleer de ontsteekafstand.
Vervang de ontsteekpen.
Vervang de ontsteekunit op het gasblok.
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intergas Comfort Line 280HRW at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intergas Comfort Line 280HRW in the language / languages: Dutch as an attachment in your email.

The manual is 2,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intergas Comfort Line 280HRW

Intergas Comfort Line 280HRW Installation Guide - Dutch - 7 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info