688781
9
Zoom out
Zoom in
Previous page
1/20
Next page
9
S
I
U
2.3
A
B
C
D
E
EN
INSTALLATION
For the unit to work, two holes Ø162 must be placed as
indicated on the template;
The maximum length of the holes is 1 m and there
must be no bends. Use the supplied grids or grids
with the same characteristics.
The holes on the wall must be drilled using suitable
equipment that facilitates your work and that does not
cause damage or excessive inconvenience to your
customer. The best tools to make big holes on walls are
special drills (called "core drills") with a high torque and
whose rotation speed can be adjusted according to the
diameter of the hole to make and to the material. To avoid
excessive dust and debris in the room, "core drills" can be
combined with suction systems consisting of a vacuum
connected to a suction cup placed next to the perforation
tip, for example.
To make the holes, proceed as follows:
- Place the drilling template provided against the wall
respecting the minimum distances: from the ceiling,
from the floor and from the side walls, indicated on
the template itself, which can be held in the correct
position by using some tape.
- Carefully mark the centre of each hole with a small drill
or a punch before actual drilling.
- Using the core drill, make two holes for inlet and outlet
air.
The holes must be drilled slightly downwards to
prevent water from entering.
The majority of the removed material is expelled outwards,
so please be careful that it doesn't hit people or objects. In
order to avoid breaking the outer plaster, be careful while
drilling the final part of the hole and ease the pressure on
the core drill.
Drill the 6 holes for the bracket as indicated on the
template.
The appliance weighs more on the right, so make sure to
secure it properly on this side. The holes must have an 8
mm diameter to accommodate the 6 supplied plugs.
A thorough examination of the characteristics and
consistency of the wall must always be carried out to
determine the number of fixing points to be made and
to choose specific plugs in particular conditions. In the
case of installation on a plasterboard or on walls with low
density, place a bracket, if necessary on the outside, that
can support the appliance safely.
The manufacturer cannot be held responsible for
any underestimation of the structural consistency
of the anchoring carried out by the installer. We,
therefore, encourage you to pay the utmost attention
to this operation as, if performed badly, it could cause
serious damage to people and objects.
Drill a hole in the position indicated on the template for
those heat-pump appliances without a condensation
drain built in the wall to allow for draining of
condensation.
A hole is also indicated on the template to secure the
appliance on the wall with an anti-lifting bracket, which
is already on the appliance.
Assembling the unit
Holes for M8 plugs
Electrical connection area
Ø162 mm holes for air channelling
Ø16 mm condensation drain
Anti-lifting bracket hole
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Innova 2.0 verticale at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Innova 2.0 verticale in the language / languages: English as an attachment in your email.

The manual is 3,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info